Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Login
loading Gif
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Comms Express Finance Options
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Browse Categories
Spend £100.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Express Finder Logo
Express Cabinet Finder
Select requirements to view suitable cabinets instantly from our entire range.
Reset
APC SRVRK1 Easy UPS Rail Kit 700mm
APC Logo

APC Easy UPS On-Line SRV 19" Rail Kit 700mm Depth

High quality, Double-conversion On-line UPS designed for essential power protection needs even in the most unstable power conditions.

These rail kits are ideal for mounting rack Easy UPS in a rack. These rail kits can support equipment measuring up to 16.75" (43cm) to 17.7" (45cm) wide.

Installation: 1. Insert 4 pieces of fixing nuts into the following locations of rail sliders. Be sure fix them firmly. Then, pull apart two ends of rail sliders and place them in a chassis. Be sure the pulling distance meets the depth of rack chassis and place fixing studs to the corresponding holes on supporting columns. For example, if depth of rack chassis is 700mm, please pull the length of rail sliders is 700mm.

2. Use 4 pieces of M6 screws to mount rail sliders into chassis.

3. According to UPS height, put 6 pieces of nuts on proper location.

4. Put UPS with assembled ears on the rail support.

5. Fix the UPS in position with 4 screws.

6. Assembly is complete.

  Additional information can be found in the User Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£20.78
£24.94 Inc Vat
Add To Cart
APC SRVRK2 Easy UPS Rail Kit 900mm
APC Logo

APC Easy UPS On-Line SRV 19" Rail Kit 900mm Depth

High quality, Double-conversion On-line UPS designed for essential power protection needs even in the most unstable power conditions.

These rail kits are ideal for mounting rack Easy UPS in a rack. These rail kits can support equipment measuring up to 16.75" (43cm) to 17.7" (45cm) wide. SRVRK1 can support equipment with a maximum weight of 60kg and SRVRK2 can support up to 100kg.

Installation: 1. Use 4 screws to mount right and left rail sliders in front.

2. Use 4 screws to mount rail sliders in back.

3. According to UPS height, put nuts on proper location

4. Put UPS on the rail support and fix the UPS in position with screws.

5. Assembly is complete.

  Additional information can be found in the User Guide PDF file

Express View Logo
In Stock: Next Day
£26.72
£32.06 Inc Vat
Add To Cart
APC ER7PDUBRKTS Easy Rack PDU Single Width Mounting Bracket, 2 Pair
APC Logo

Easy Rack PDU mounting bracket

Single width, 2 pairs


Installation Install the cage nut:

1. From the inside of the rack, insert the cage nut into the square hole.

2. Hook one tab of the cage nut assembly through the far side of the hole.

3. Place the cage nut tool on the other side of the cage nut and pull to snap into position.

Install the Mounting Brackets:

Using the hardware provided, install the Mounting Brackets in the location where you plan to install your Rack PDU or other equipment. There are four Mounting Brackets in the Kit; two (2) for the left side of the rack and two (2) for the right side of the rack.

Make sure to position the Mounting Brackets so that the small end of the cut out is at the bottom so the toolless mounting peg of a Rack PDU installs securely.

The Easy Rack in the illustration is shown without doors or side panels for clarity

 
Physical Colour Black Net Weight 1 kg
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 2-3 Weeks
£20.78
£24.94 Inc Vat
Add To Cart
APC ER7DCM Easy Rack Cable Manager 1U
APC Logo

Easy Rack 1U Cable Manager in Depth


Installation The 1U Cable Manager is installed to the front and rear vertical mounting rails on either side of your Easy Rack. The 1U Cable Manager can be adjusted to fit the depth of your Easy Rack. From the center of the mounting holes, the Cable manager can be extended from the minimum depth of 383mm (15.08 in.) to the maximum of 573mm (22.56 in.).

Use the four (4) M5 x 10 Phillips head screws provided to install the 1U Cable Manager to the round holes on the inside edge of the front and rear vertical mounting rails.

 
Physical Net Weight 0.5 kg Color Black
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: Next Day
£21.77
£26.12 Inc Vat
Add To Cart
APC ER7BTM04 Easy Bottom Post Support Mounting Brackets 3-4FT One Pair
APC Logo

APC ER7BTM04 Easy Bottom Post Support Mounting Brackets

3-4FT, one pair

Easy Rack Accessories Includes: Brackets


Installation Install each bracket using two (2) M8 x 12 T30 screws and one (1) M6 x 12 T25 screw as shown in the illustration below.

 
Physical Net Weight 1 kg Color Black
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£23.94
£28.73 Inc Vat
Add To Cart
APC ER7HCM Easy Rack Horizontal Cable Manager 1U
APC Logo

Easy Rack 1U Horizontal Cable Manager


Installation Install the cage nut:

1. From the inside of the rack, insert the cage nut into the square hole.

2. Hook one tab of the cage nut assembly through the far side of the hole.

3. Place the cage nut tool on the other side of the cage nut and pull to snap into position.

Install the Horizontal Cable Manager:

Using the hardware provided, install the four (4) cage nuts in the vertical mounting rails of your Easy Rack.

Use the four (4) M6 x 12 Pan head T30 screws to secure the Horizontal Cable Manager to the cage nuts.

 
Physical Maximum Height 45 mm, 4.45 cm Maximum Width 483 mm, 48.3 cm Net Weight 1 kg Color Black
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: Next Day
£26.72
£32.06 Inc Vat
Add To Cart
APC ER7PDUBRKT Easy Rack PDU Double Width Mounting Bracket 2 Pair
APC Logo

Easy Rack PDU mounting bracket

Double width, 2 pairs


Installation Install the cage nut:

1. From the inside of the rack, insert the cage nut into the square hole.

2. Hook one tab of the cage nut assembly through the far side of the hole.

3. Place the cage nut tool on the other side of the cage nut and pull to snap into position.

Install the Mounting Brackets:

Using the hardware provided, install the Mounting Brackets in the location where you plan to install your Rack PDU or other equipment. There are four Mounting Brackets in the Kit; two (2) for the left side of the rack and two (2) for the right side of the rack.

Make sure to position the Mounting Brackets so that the small end of the cut out is at the bottom so the toolless mounting peg of a Rack PDU installs securely.

The Easy Rack in the illustration is shown without doors or side panels for clarity

 
Physical Colour l Net Weight 1 kg
Installation details can be found in the Installation Guide PDF file

Express View Logo
Out Of Stock
£37.61
£45.13 Inc Vat
Add To Cart
APC ER7HWKIT EasyRack M6 Hardware Kit
APC Logo
32 sets of M6 cage nuts, nylon washers,slot/phillips screws

Easy Rack, M6 Hardware Kit

32 sets of M6 cage nuts, nylon washers, slot phillips screws


Physical Maximum Height 25 mm, 2.5 cm Maximum Width 13 mm, 1.3 cm Maximum Depth 13 mm, 1.3 cm Net Weight 0.36 kg
Technical Specifications can be found in the Technical Specifications PDF file

Express View Logo
In Stock: 1-2 Weeks
£43.94
£52.73 Inc Vat
Add To Cart
APC ER7BP1U Easy Rack 1U metal blanking panel, 10 Pack
APC Logo

Easy Rack 1U metal blanking panel

Includes: (10) 1U panels, Mounting hardware

Airflow Management Blanking Panel Kit of 1U sheet metal panels to prevent air recirculation by occupying unused rack space.


Installation Install the cage nut:

1. From the inside of the rack, insert the cage nut into the square hole.

2. Hook one tab of the cage nut assembly through the far side of the hole

3. Place the cage nut tool on the other side of the cage nut and pull to snap into position.

Install the Blanking panel:

The 1U Blanking panel can be installed in an empty U space in your Easy Rack. Each blanking panel is installed to the vertical mounting rails using four (4) M6 x 12 Pan head screws and four (4) cage nuts.

 
Physical Maximum Height 44 mm, 4.4 cm Net Weight 3.0 kg >Color Black
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: Next Day
£52.46
£62.95 Inc Vat
Add To Cart
APC ER7RCC24 Easy Rack Vertical 0U Accessory, 24U, Quanity 2
APC Logo

Easy Rack Vertical 0U accessory channel

24U, qty. 2


Installation Use four (4) M5 x 10 Phillips head screws provided to install the 0U Vertical Accessory Channel to the top and bottom side supports in the rear of the rack. The 24U Easy Rack in the illustration below is shown from the rear with the doors removed for clarity.

 
Physical Maximum Height 1075 mm, 107.5 cm Maximum Width 129 mm, 12.9 cm Maximum Depth 10 mm, 1 cm Net Weight 3 kg Colour Black
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£57.94
£69.53 Inc Vat
Add To Cart
APC ER7BP2U Easy Rack 2U metal blanking panel - 10 pack
APC Logo

Easy Rack 2U metal blanking panel

Includes: (10) 2U panels, Mounting hardware

Airflow Management Blanking Panel Kit of 2U sheet metal panels to prevent air recirculation by occupying unused rack space.


Installation Install the cage nut:

1. From the inside of the rack, insert the cage nut into the square hole.

2. Hook one tab of the cage nut assembly through the far side of the hole

3. Place the cage nut tool on the other side of the cage nut and pull to snap into position.

Install the Blanking panel:

The 2U Blanking panel can be installed in an empty 2U space in your Easy Rack. Each blanking panel is installed to the vertical mounting rails using four (4) M6 x 12 Pan head screws and four (4) cage nuts.

 
Physical Maximum Height 44 mm, 4.4 cm Net Weight 6.0 kg >Color Black
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: Next Day
£62.36
£74.83 Inc Vat
Add To Cart
APC ER7BTM05 Easy Bottom Post Support Mounting Brackets 4-5FT One Pair
APC Logo

APC ER7BTM05 Easy Bottom Post Support Mounting Brackets

4-5FT, one pair

Easy Rack Accessories Includes: Brackets


Installation Install each bracket using two (2) M8 x 12 T30 screws and one (1) M6 x 12 T25 screw as shown in the illustration below.

 
Physical Net Weight 2 kg Color Black
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£63.94
£76.73 Inc Vat
Add To Cart
APC ER7SHELFS Easy Rack component short shelf - 50KG
APC Logo

Easy Rack 50 kg component shelf short


Installation Install the cage nut:

1. From the inside of the rack, insert the cage nut into the square hole.

2. Hook one tab of the cage nut assembly through the far side of the hole.

3. Place the cage nut tool on the other side of the cage nut and pull to snap into position.

Install the 50 kg Accessory Shelf

Install four (4) cage nuts to the front two vertical mounting rails as described above. Install four (4) cage nuts to the inside of the rear vertical mounting rails as described above. At the front of the rack, attach four (4) screws to the front of the shelf and into the four (4) cage nuts you installed in the vertical mounting rails. At the rear of the rack, install four (4) screws to the rails on the rear of the shelf and through the four (4) cage nuts installed in the vertical mounting rails. The illustration below shows this installation process.

 
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£68.94
£82.73 Inc Vat
Add To Cart
APC ER7SHELF Easy Rack Adjustable shelf - 50KG
APC Logo

Easy Rack 50 kg Adjustable shelf


Installation Install the cage nut:

1. From the inside of the rack, insert the cage nut into the square hole.

2. Hook one tab of the cage nut assembly through the far side of the hole.

3. Place the cage nut tool on the other side of the cage nut and pull to snap into position.

Install the 50 kg Accessory Shelf

Install four (4) cage nuts (provided) to the two front vertical mounting rails as described above. Install four (4) cage nuts (provided) to the inside of the two rear vertical mounting rails as described above. At the front of the rack, attach four (4) M6 x 12 pan head T30 screws (provided) to the front of the shelf and into the four (4) cage nuts you installed in the vertical mounting rails. At the rear of the rack, install four (4) M6 x 12 pan head T30 screws (provided) to the adjustable rails on the rear of the shelf and through the four (4) cage nuts installed in the vertical mounting rails. The illustration below shows this installation process.

 
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£83.94
£100.73 Inc Vat
Add To Cart
APC ER7BTM06 Easy Bottom Post Support Mounting Brackets 5-6FT - One pair
APC Logo

APC ER7BTM06 Easy Bottom Post Support Mounting Brackets

5-6FT, one pair

Easy Rack Accessories Includes: Brackets


Installation Install each bracket using two (2) M8 x 12 T30 screws and one (1) M6 x 12 T25 screw as shown in the illustration below.

 
Physical Net Weight 2.5 kg Color Black
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£84.94
£101.93 Inc Vat
Add To Cart
APC ER7RCC42 Easy Rack Vertical 0U Accessory, 42U, Quantity 2
APC Logo

Easy Rack Vertical 0U accessory channel

42U, qty. 2


Installation Install the 0U Vertical Accessory Channel 42U to the top and bottom of the side supports in the rear of the rack with four (4) M5 x 10 Phillips head screws provided. The 42U Easy Rack in the illustration is shown from the rear with the doors removed for clarity.

 
Physical Maximum Height 1868 mm, 186.8 cm Maximum Width 129 mm, 12.9 cm Maximum Depth 10 mm, 1 cm Net Weight 6 kg Colour Black
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: Next Day
£89.09
£106.91 Inc Vat
Add To Cart
APC ER7VCM42 Easy Rack Vertical Cable Manager 42U
APC Logo

Easy Rack 42U Vertical Cable Manager

For 800mm W racks


Installation Install the Vertical Cable Manager:

Remove the eight (8) M4 x 6 screws from the two (2) Vertical Cable Manager Covers.

Use the ten (10) M5 x 10 screws to install the Vertical Cable Manager Body to the vertical mounting rails of your Easy Rack.

Install the Covers to the Vertical Cable Manger Body using the eight (8) M4 x 6 screws you removed when removing the Covers.

 
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: Next Day
£98.94
£118.73 Inc Vat
Add To Cart
APC ER7RCC48 Easy Rack Vertical 0U Accessory, 48U, Quantity 2
APC Logo

Easy Rack Vertical 0U accessory channel

48U, qty. 2


Installation Install the 0U Vertical Accessory Channel 48U to the top and bottom side supports in the rear of the rack with four (4) M5 x 10 Phillips head screws provided. The 48U Easy Rack in the illustration is shown from the rear with the doors removed for clarity

 
Physical Maximum Height 2135 mm, 213.5 cm Maximum Width 129 mm, 12.9 cm Maximum Depth 10 mm, 1 cm Net Weight 7 kg Colour Black
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£104.94
£125.93 Inc Vat
Add To Cart
1000mm Deep Black Qty 2
APC Logo

Easy Rack Side Panel 42U/1000mm Side Panels

Black Deep Split Qty 2


Installation Bottom Panel:

1. Install the bottom panel first. Tilt the panel into the side brace on the bottom of the rack as shown in the illustration.

2. Bring the panel up into position over the side brackets located on the rack.

Top Panel:

3. Install the bottom edge of the top panel over the top edge of the bottom panel.

4. Tilt the panel up into position.

5. Lock the top panel with the key to secure it into position. The lock latch in the vertical (locking) position fits behind the top side brace.

 
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£113.94
£136.73 Inc Vat
Add To Cart
APC ER7VCM48 Easy Rack Vertical Cable Manager 48U
APC Logo

Easy Rack 48U Vertical Cable Manager

For 800mm W racks


Installation Install the Vertical Cable Manager:

Remove the eight (8) M4 x 6 screws from the two (2) Vertical Cable Manager Covers.

Use the ten (10) M5 x 10 screws to install the Vertical Cable Manager Body to the vertical mounting rails of your Easy Rack.

Install the Covers to the Vertical Cable Manger Body using the eight (8) M4 x 6 screws you removed when removing the Covers.

 
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£119.94
£143.93 Inc Vat
Add To Cart
1200mm Deep Black Qty 2
APC Logo

Easy Rack Side Panel 42U/1200mm Side Panels

Black Deep Split Qty 2


Installation Bottom Panel:

1. Install the bottom panel first. Tilt the panel into the side brace on the bottom of the rack as shown in the illustration.

2. Bring the panel up into position over the side brackets located on the rack.

Top Panel:

3. Install the bottom edge of the top panel over the top edge of the bottom panel.

4. Tilt the panel up into position.

5. Lock the top panel with the key to secure it into position. The lock latch in the vertical (locking) position fits behind the top side brace.

 
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: Next Day
£128.69
£154.43 Inc Vat
Add To Cart
1000mm Deep Black Qty 2
APC Logo

Easy Rack Side Panel 42U/1200mm Side Panels

Black Deep Split Qty 2


Installation Bottom Panel:

1. Install the bottom panel first. Tilt the panel into the side brace on the bottom of the rack as shown in the illustration.

2. Bring the panel up into position over the side brackets located on the rack.

Top Panel:

3. Install the bottom edge of the top panel over the top edge of the bottom panel.

4. Tilt the panel up into position.

5. Lock the top panel with the key to secure it into position. The lock latch in the vertical (locking) position fits behind the top side brace.

 
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£136.94
£164.33 Inc Vat
Add To Cart
1200mm Deep Black Qty 2
APC Logo

Easy Rack Side Panel 48U/1200mm Side Panels

Black Deep Split Qty 2


Installation Bottom Panel:

1. Install the bottom panel first. Tilt the panel into the side brace on the bottom of the rack as shown in the illustration.

2. Bring the panel up into position over the side brackets located on the rack.

Top Panel:

3. Install the bottom edge of the top panel over the top edge of the bottom panel.

4. Tilt the panel up into position.

5. Lock the top panel with the key to secure it into position. The lock latch in the vertical (locking) position fits behind the top side brace.

 
Installation details can be found in the Installation Guide PDF file

Express View Logo
In Stock: 1-2 Weeks
£154.94
£185.93 Inc Vat
Add To Cart
Other Ranges Available
APC Easy Racks
APC Easy Racks
View Range
APC Netshelter SX Server Racks
APC Netshelter SX Server Racks
View Range
APC NetShelter Airflow Management
APC NetShelter Airflow Management
View Range
APC NetShelter Cable Management
APC NetShelter Cable Management
View Range
APC NetShelter Mounting Hardware
APC NetShelter Mounting Hardware
View Range
Join Our Mailing List
Social Links
  • Apply for Credit