.jpg)
Contains
Fluke Networks MS2-MAG-KIT HOLSTER WITH MAGNETIC STRAP FOR MS2, FI-500, SFP AND MFP
Key Features
Attaches to any magnetic surface using the strong rare-earth magnet
Built in hole to attach the strap to j-hooks in your data rack
Folds the strap to create a simple stand for the meter
Works with MicroScanner™, SimpliFiber® Pro, FI-500, MultiFiber™ Pro
.jpg)
Four types of Fluke Networks Singlemode TRC 2m are available:
Multimode test reference cord (2m) for testing 50µm SC terminated fibers (SC/SC)
Multimode test reference cord (2m) for testing 50µm LC terminated fibers (LC/LC)
Multimode test reference cord (2m)for testing 50µm FC terminated fibers (FC/FC)
Multimode test reference cord (2m) for testing 50µm ST terminated fibers (ST/ST)
Connector Type: |
.jpg)
Seven types of Fluke Networks Singlemode TRC 2m are available:
Singlemode test reference cord (2m) for testing SC terminated fibers (SC/SC)
Singlemode test reference cord (2m) for testing LC terminated fibers (SC/LC)
Singlemode test reference cord (2m) for testing FC terminated fibers (SC/FC)
Singlemode test reference cord (2m) for testing ST terminated fibers (SC/ST)
Singlemode test reference cord (2m) for testing LC terminated fibers (LC/LC)
Singlemode test reference cord (2m) for testing FC terminated fibers (FC/FC)
Singlemode test reference cord (2m) for testing ST terminated fibers (ST/ST)
Connector Type: |
.jpg)
Four types of Fluke Networks Singlemode TRC 2m are available:
Multimode Encircled Flux compliant test reference cord (2m) for testing 62.5um SC terminated fibers (SC/SC)
Multimode Encircled Flux compliant test reference cord (2m) for testing 62.5um LC terminated fibers (SC/LC)
Multimode Encircled Flux compliant test reference cord (2m)for testing 62.5um FC terminated fibers (SC/FC)
Multimode Encircled Flux compliant test reference cord (2m) for testing 62.5um ST terminated fibers (SC/ST)
Connector Type: |
.jpg)
Seven types of Fluke Networks Singlemode TRC Kit 2m are available:
Singlemode test reference cord kit (2m) for testing SC terminated fibers (4 SC/SC)
Singlemode test reference cord kit (2m) for testing LC terminated fibers (2 SC/LC, 2 LC/LC)
Singlemode test reference cord kit (2m) for testing FC terminated fibers (2 SC/FC, 2 FC/FC)
Singlemode test reference cord kit (2m) for testing ST terminated fibers (2 SC/ST, 2 ST/ST)
Singlemode TRC KIT 2m (2 SCUPC/SCAPC,2 SCAPC/SCAPC)
Singlemode TRC KIT 2m (2 SCUPC/LCAPC,2 LCAPC/LCAPC)
Singlemode TRC KIT 2m (2 SCUPC/E2KAPC, 2 E2KAPC/E2KAPC)
Connector Type: |
.jpg)
The EXTD TIP SN/MDC Series 2 extended probe tip is a fibre inspection accessory designed to support access to recessed female SN and MDC connectors. It extends the reach of inspection guides used with compatible Fluke FiberInspector Ultra systems, allowing technicians to align inspection probes more effectively in dense fibre environments where connector ports are positioned deeper within panels or housings.
Key Features of Fluke EXTD TIP SN/MDC
Designed for recessed female SN and MDC fibre connector inspection
Extends reach of S2 inspection guide systems for improved physical access
Supports use with Fluke FiberInspector Ultra platforms
Helps maintain alignment between probe and fibre end face in tight installations
Built for use in high-density fibre network environments
Purpose in Fibre Inspection
This extended probe tip is used when standard inspection attachments cannot physically reach the fibre end face. It ensures the inspection camera system can be positioned correctly for accurate viewing of connector surfaces inside compact hardware layouts.
Application Use Case
Commonly used in data centre environments and structured cabling systems where SN and MDC connectors are installed in recessed patch panels. It supports technicians performing routine inspection and maintenance tasks in high-density fibre installations.
Integration with Inspection Systems
The accessory works as part of the Fluke S2 inspection ecosystem, pairing with compatible guides and FiberInspector Ultra devices to extend functional reach without altering inspection workflow.
.jpg)
The Fluke MDC-EXTD TIP KIT Series 2 is designed to support inspection of recessed female MDC fiber connectors where standard probe tips cannot easily reach. It pairs an extended tip with a guiding component to maintain alignment and access in high-density fiber environments commonly found in structured cabling.
Key Features of Fluke MDC-EXTD TIP KIT
Extended reach design for recessed female MDC connector inspection
Guide component ensures stable alignment during endface viewing
Compatible with Series 2 fiber inspection platforms
Supports inspection in high-density patch panel environments
Designed for accurate fiber endface contamination detection
Recessed Connector Access
Built to reach deep-mounted MDC ports, the kit allows inspection in locations where standard tips cannot physically engage the connector surface. This makes it suitable for dense fibre rack layouts.
Alignment Stability
The included guide component helps maintain consistent positioning between the inspection probe and connector face, reducing misalignment during imaging.
Inspection Workflow Use
This kit is typically used during fibre certification and maintenance routines, supporting technicians working with structured fibre networks that rely on MDC connector formats.
.jpg)
The Fluke MDC-MDC-SM UPC TRC is a single-mode test reference cord designed for precise fiber optic certification workflows involving MDC connectivity. Built for controlled measurement environments, it supports repeatable calibration when verifying insertion loss across structured fiber links. Its MDC-to-MDC interface, paired with SC UPC compatibility in test setups, allows technicians to establish a stable reference baseline for consistent optical testing across installation and maintenance tasks.
This test reference cord is intended for calibration procedures where fiber link accuracy must be verified before certification. It helps establish a controlled baseline in optical loss testing, ensuring results remain consistent when evaluating MDC-based cabling systems in structured network installations.
Key Features of Fluke MDC-MDC-SM UPC TRC
Single-mode 9/125 µm fiber construction for accurate signal transmission
MDC-to-MDC interface designed for modern high-density fiber systems
UPC polished connectors for low-reflection performance
Used in fiber certification and insertion loss measurement workflows
Supports Fluke Versiv and CertiFiber Pro testing environments
Reference-grade build for repeatable measurement consistency
Build & Design
The cord is manufactured with single-mode glass and UPC-end polished connectors to reduce signal loss and reflection. Its construction is intended for repeatable handling in lab and field testing conditions, supporting stable performance across multiple measurement cycles.
.jpg)
The Fluke NFA-MDC-V1-ADP MDC Universal Adapter is a fiber optic interface accessory designed for use with Fluke Networks certification tools. It provides a connection point between MDC duplex fiber connectors and compatible test equipment, supporting measurement and verification tasks in structured cabling environments where high-density fiber formats are in use.
Key Features of Fluke NFA-MDC-V1-ADP
Designed for MDC (Mini Duplex Connector) fiber optic interfaces
Supports fiber loss testing and certification workflows
Used with Fluke Networks optical test equipment
Enables connection between MDC cabling and test instrument ports
Suitable for high-density data center fiber installations
Typically used in pairs for end-to-end link testing
Requires 2x adapters for MDC-to-MDC certification
Attaches to the set's power meter port
Application Context
This adapter is commonly used in environments where modern MDC fiber cabling is deployed. It allows technicians to interface test instruments with compact connector systems, making it suitable for commissioning, maintenance, and verification of structured fiber links.
Integration with Test Systems
The adapter connects directly to compatible Fluke fiber certification platforms, enabling consistent reference testing setups. It is used as part of a controlled testing arrangement to measure insertion loss and confirm compliance in installed fiber networks.
.jpg)
The Fluke PROBE TIP 1.25 MALE Series 2 Slim Probe Tip is a compact fibre inspection accessory designed for precise access to 1.25 mm male ferrule connectors. It is used with Fluke Networks fibre inspection systems to support clear viewing of connector end faces in dense or confined patching environments where standard probe tips cannot easily reach.
Key Features of Fluke PROBE TIP 1.25 MALE
Supports inspection of 1.25 mm male ferrule connectors
Compatible with Fluke Networks Series 2 inspection platforms
Suitable for high-density fibre patch panels and adapters
Interchangeable tip format for flexible field use
Assists in identifying contamination and end-face damage
Designed for Dense Fibre Environments
This probe tip is built for situations where fibre connectors are positioned closely together. Its narrow structure allows technicians to position the inspection camera accurately without disturbing adjacent connections.
Connector Compatibility Focus
It is specifically intended for 1.25 mm male ferrule interfaces, commonly found in modern fibre architectures. This makes it suitable for inspecting compact connector types used in structured network deployments.
Integration with Inspection Systems
The tip attaches to Fluke Networks fibre inspection devices as part of a modular system. This allows quick switching between different tip types depending on connector geometry and inspection requirements.
.jpg)
The Fluke S2 GUIDE MDC FEMALE Series 2 guide is built for accurate inspection of female MDC connectors in dense fiber environments. Designed for use with compatible FiberInspector probes, this guide helps position the inspection tip correctly within recessed connector ports, making it easier to examine fiber endfaces in patch panels and high-capacity network installations. Its compact form supports consistent alignment during inspections while helping technicians work efficiently in limited-access areas.
Key Features of Fluke S2 GUIDE MDC FEMALE
Designed for female MDC connector inspection
Part of the Fluke Networks Series 2 accessory range
Supports inspection in high-density fiber panels
Compatible with FiberInspector inspection cameras
Helps maintain accurate probe alignment
Suitable for recessed connector applications
Compact guide format for controlled positioning
Designed for MDC Connector Access
The Series 2 guide is specifically shaped for female MDC connectors, allowing inspection probes to reach ports that are difficult to access using standard inspection tips. This makes it useful in modern fiber infrastructures where space is limited.
Supports Consistent Fiber Inspection
By guiding the inspection probe into the correct position, the accessory helps technicians capture clear views of fiber endfaces during maintenance, installation, and troubleshooting tasks.
Built for High-Density Environments
Commonly used in data centers and structured cabling systems, the guide is suited for environments where MDC connectors are deployed to maximize fiber capacity within compact network hardware.
Compatible with Fluke FiberInspector Systems
The guide integrates with supported Fluke FiberInspector cameras and related Series 2 accessories, allowing technicians to adapt inspection tools for a wide range of connector types and panel layouts.
.jpg)
The Fluke S2 GUIDE SN FEMALE is built for accurate inspection access to female SN fiber connectors in dense cabling environments. Designed for use with compatible Fluke FiberInspector scopes, this Series 2 guide helps technicians inspect recessed connector end faces inside modern patch panels and high-density fiber systems. Its precision fit supports stable alignment during inspections, making it a practical accessory for structured cabling, data center maintenance, and fiber deployment workflows.
Key Features of Fluke S2 GUIDE SN FEMALE
Designed specifically for female SN fiber connectors
Part of the Fluke Networks Series 2 inspection guide range
Supports inspection in high-density fiber environments
Compatible with Fluke FiberInspector inspection scopes
Helps align inspection probes within recessed ports
Suitable for patch panels, cassettes, and structured cabling systems
Compact accessory for field and lab inspection tasks
Built for High-Density Fiber Access
The guide is intended for environments where connector spacing is limited and direct inspection access can be difficult. Its form factor allows easier positioning inside crowded fiber panels commonly used in modern network infrastructure.
Reliable Connector Alignment
When paired with compatible Fluke inspection equipment, the guide assists with steady probe placement for clearer end-face viewing. This can help reduce handling movement during fiber inspection procedures.
Designed for Modern SN Connectivity
SN connectors are increasingly used in high-density installations where space efficiency is important. The S2 GUIDE SN FEMALE is tailored for these connector types, supporting inspection workflows across data centers and advanced fiber networks.
Compact and Easy to Deploy
Its lightweight design makes it easy to carry alongside inspection scopes and fiber testing accessories. The guide can be quickly attached when working across multiple inspection points during installation or maintenance tasks.
.jpg)
The Fluke SN-EXTD TIP KIT is built for inspecting recessed female SN fiber connectors in compact, high-density network environments. Combining a Series 2 guide with an extended inspection tip, this kit provides improved access to difficult-to-reach connector endfaces inside tightly packed panels and transceivers. Designed for compatibility with Fluke FiberInspector systems, it supports accurate fiber inspection workflows while helping technicians work efficiently in modern data center installations.
Key Features of Fluke SN-EXTD TIP KIT
Designed for female SN connector inspection
Includes Series 2 SN female guide and extended probe tip
Provides access to recessed connector interfaces
Compatible with Fluke FiberInspector inspection cameras
Supports high-density fiber environments
Suitable for SN connector maintenance and verification
Extended Reach for Recessed Connectors
The included extended tip allows technicians to inspect fiber connectors positioned deeper inside patch panels and networking equipment where standard tips may not reach comfortably. This added reach helps simplify inspection tasks in confined spaces.
.jpg)
The Fluke TIP W/BEND LC APC FM short extended tip is built for inspecting recessed LC APC female fiber connectors in tight network spaces where standard probe tips can be difficult to position. Its bent profile provides improved access inside high-density patch panels, transceivers, and crowded fiber enclosures, helping technicians carry out clear and accurate end-face inspections during installation, maintenance, and troubleshooting work.
Key Features of Fluke TIP W/BEND LC APC FM
Short extended inspection tip with bent design
Designed for LC APC female connectors
Provides access to recessed fiber ports
Compatible with Fluke FiberInspector inspection scopes
Suitable for high-density fiber environments
Supports accurate fiber end-face inspection
Built for APC polished connector applications
Designed for Tight Access Areas
The angled tip configuration allows technicians to inspect fiber connectors located inside crowded cabinets, transceivers, and compact patching systems without awkward positioning or limited visibility.
Built for LC APC Connectivity
This inspection tip is specifically intended for LC APC female connectors, making it suitable for fiber networks that require angled physical contact connections for reduced back reflection.
Supports Cleaner Fiber Inspections
By improving physical access to difficult connector locations, the tip assists technicians in checking for contamination, scratches, and debris before network connections are completed.