X
Forgotten Password?
Retry
Login
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Browse Categories
More Info
Tripp Lite ATS (Auto-Transfer Switch) PDU provides a redundant power option for critical networking equipment.
Single-Phase Metered Automatic Transfer Switch, 2 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA

PDUMH15HVAT Overview

The PDUMH15HVAT 2–2.4kW Single-Phase 200–240V Metered Automatic Transfer Switch / ATS PDU enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features 10 C13 outlets.

Dual 3.6-meter input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources in a nominal voltage range from 200–240V. Plug lock inserts prevent cords from accidental disconnection. The PDUMH15HVAT constantly evaluates the power quality of both input sources.

Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 2–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.

Built-in slot supports the optional WEBCARDLX (sold separate), which turn the PDUMH15HVAT into a switched PDU by allowing remote access to the PDU for power monitoring, configuration, outlet control and notifications via web browser, SSH, telnet or SNMP. Digital ammeter monitors total output current. LEDs display outlet on/off status and input power status on primary and secondary inputs.  
PDUMH15HVAT Features

Single-phase IEC-320 C14 input and 200–240V output


Digital load meter for real-time output current monitoring


10 C13 outlets
Mounts in 1U of space in EIA-standard 19 in. racks


Automatic transfer switching within 5 ms


2-year limited warranty
  PDUMH15HVAT Package Includes


TAA-Compliant 2–2.4kW Single-Phase ATS/Metered PDU
(10) C14 plug lock inserts
(6) Screws (2) C13 to C14 power cords, 3.6 m (11.8 ft.)
Rack mounting hardware
Owner's manual  

View More
In Stock: Next Day
£288.94
£346.73 Inc Vat
Qty:
1U Rack-Mount

Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable.

Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application.

ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.

Key Features 200-240V 16/20A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 16A continuous)
Provides a redundant power option for critical networking equipment with a single input power cord
2 digit display reports output power consumption in amps
1U horizontal rackmount form factor; 14.8 in. / 37.6 cm depth
10 outlets (8 C13, 2 C19)
Set of two C20 inlets support connection to separate PRIMARY and SECONDARY power sources
Two 12ft / 3.6m C19 to C20 power cables included
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
Super-fast switchover between primary and secondary power sources occurs in 2-5 milliseconds
Built-in card slot supports optional SNMPWEBCARD or WEBCARDLX for permanent upgrade to a switched & monitored PDU system
Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup
Front panel LEDs confirm power availability on both input lines
Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases

This Package Includes Metered PDU with ATS Support
User manual with warranty information

View More
In Stock: Next Day
£284.72
£341.66 Inc Vat
Qty:
Single-Phase Switched Automatic Transfer Switch, 2 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA

PDUMH15HVATNET Overview

Recommended for data centers, server rooms and network closets, this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-foot (3.7-meter) input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids.

Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.

Dynamic solid-state automatic transfer switching (ATS) allows the IEC C13 PDU to switch to the secondary source within 2–5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source.  
PDUMH15HVATNET Features

8 switched and 2 unswitched 200–240V C13 outlets distribute power to connected equipment


Built-in Java-free HTML5-based LX Platform interface allows you 24/7 remote access


Auto Probe for Autonomous Device Management


To enable the Auto Probe feature, this product requires LX firmware update 15.5.2 or later to be installed
Dual 12 ft. input cords with C14 plugs connect to separate primary/secondary power sources


Remote power monitoring and control reduces on-site visits and maintenance costs


Mounts horizontally in 1U of space in common 19 in. racks for easy installation


2-year limited warranty
  PDUMH15HVATNET Package Includes


2–2.4kW Single-Phase ATS/Switched PDU
Built-in LX Platform interface
(12) Plug-lock insert sleeves
Owner's manual (2) C13 to C14 power cords, 12 ft. (3.7 m)
Rack-mounting hardware
Configuration cable  

View More
In Stock: Next Day
£555.10
£666.12 Inc Vat
Qty:
1U Rack-Mount

The PDUMNH16HVAT 3.7kW Single-Phase 230V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an IEC309 16A Blue outlet for connecting a single device or a 0U 230V vertical PDU with IEC309 16A Blue plug. 

Dual 10-foot input cords with IEC309 16A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable to ensure connected equipment remains powered.

Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent overloads, power loss and downtime. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).

Key Features Primary and Secondary Inputs for Power Redundancy
Offers remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
IEC309 16A Blue (2P+E) inputs with 10 ft. cords connect to separate primary and secondary single-phase power sources
Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to a separate UPS

Built-In IEC309 16A Blue Outlet

Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC309 16A Blue input (sold separately)

Automatic Transfer Switching

Dynamic solid-state (TRIAC) automatic transfer switching
Switches to secondary power source if primary source fails or becomes unstable
1–5 ms transfer time ensures uninterrupted operation of connected equipment
Built-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source

Multifunction Digital Display with LEDs

Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor

Advanced Network Monitoring

Built-in Ethernet network interface allows full remote access for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP
Real-time load/current data with billing-grade accuracy (+/- 1 percent)
Tiered access privileges allow both an administrator and guest to log in
Optional ENVIROSENSE module (sold separately) monitors temperature and humidity

Broad Communications Compatibility

Supports HTTP, HTTPS, PowerAlert® Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP
10/100 Mbps auto-sensing for communication with 10/100 Base-T networks

Mounts Horizontally in 1U of Rack Space
Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
Optional PDU4PKIT rail kit (sold separately) adds rear mounting support

This Package Includes PDUMNH16HVAT 3.7kW Single-Phase 230V ATS/Monitored PDU
Rack-mounting brackets
Owner’s manual

View More
In Stock: 7-10 Days
£576.10
£691.32 Inc Vat
Qty:
1U Rack-Mount

The PDUMNH32HVAT 7.4kW Single-Phase 230V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an IEC 309 32A Blue outlet for connecting a single device or an additional 230V PDU with IEC 309 32A Blue plug, such as Tripp Lite’s PDUMV32HV. 

Dual 10-foot (3-meter) input cords with IEC 309 32A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. To ensure connected equipment remains powered, dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable.

Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent overloads, power loss and downtime. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).

Key Features Primary and Secondary Inputs for Power Redundancy
Offers remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
IEC 309 32A Blue (2P+E) inputs with 10 ft. (3 m) cords connect to separate primary and secondary single-phase power sources
Fault-tolerant, hot-swappable UPS protection when used with single UPS
Fully redundant UPS protection when each cord is connected to separate UPS

Built-In IEC 309 32A Blue Outlet
Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC 309 32A Blue (2P+E) input (sold separately)

Automatic Transfer Switching
Dynamic solid-state (TRIAC) automatic transfer switching
Switches to secondary power source if primary source fails or becomes unstable
1–5 ms transfer time ensures uninterrupted operation of connected equipment
Built-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source

Multifunction Digital Display with LEDs
Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor

Advanced Network Monitoring
Built-in Ethernet network interface allows full remote access for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP
Real-time load/current data with billing-grade accuracy (+/- 1 percent)
Tiered access privileges allow both an administrator and guest to log in
Optional ENVIROSENSE module (sold separately) monitors temperature and humidity

Broad Communications Compatibility
Supports HTTP, HTTPS, PowerAlert® Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP
10/100 Mbps auto-sensing for communication with 10/100 Base-T networks

Mounts Horizontally in 1U of Rack Space
Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
Included PDU4PKIT rail kit adds rear rack-mounting support

This Package Includes PDUMNH32HVAT 7.4kW Single-Phase 230V ATS/Monitored PDU
Rack-mounting brackets
PDU4PKIT rear support rail kit
Owner’s manual

View More
In Stock: 7-10 Days
£612.12
£734.54 Inc Vat
Qty:
Single-Phase Metered Automatic Transfer Switch, 2 230V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA

PDUMH32HVAT Overview

The PDUMH32HVAT 7.4kW Single-Phase 230V Metered Automatic Transfer Switch / ATS PDU provides power monitoring and enables redundant power for network devices with non-redundant power supply configurations.

Ideal for data centers and server rooms, it mounts in 2U of space in EIA-standard 19-inch racks and features 18 outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker.   Dual three-meter input cords with IEC 309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 230V power sources. The PDU constantly evaluates the power quality of both input sources.

Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.   Multifunction digital display with LED indicators reports output current, voltage and kW loading information.
PDUMH32HVAT Features

Single-phase IEC 309 32A Blue (2P+E) input and 230V output


Automatic transfer switching within 1–5 ms


Multifunction digital display with LED indicators
16 C13 and 2 C19 outlets in 2 load banks


Mounts in 2U of space in EIA-standard 19 in. racks


2-year limited warranty
  PDUMH32HVAT Package Includes


7.4kW Single-Phase 230V ATS/Metered PDU
Rack-mounting brackets
Owner's manual Plug-lock cable retention sleeves
Cable ties  

View More
In Stock: Next Day
£661.62
£793.94 Inc Vat
Qty:

The PDUMH32HVATNET 7.4kW Single-Phase 230V ATS/Switched PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 2U of space in EIA-standard racks and features 18 switched outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker.

Dual 3-meter input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 230V power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.

Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Supports user-programmable startup of outlets in any order or interval to ensure network items are turned on in the proper sequence and reliably discovered.

Digital LED display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity with the optional temperature sensor (sold separately).

Key Features Primary and Secondary Inputs for Power Redundancy
Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
Dual 3m input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase power sources

Automatic Transfer Switching
Dynamic solid-state (TRIAC) automatic transfer switching
Switches to secondary power source if primary source fails or becomes unstable
1–5 ms transfer time ensures uninterrupted operation of connected equipment
Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source

Multifunction Digital LED Display
Reports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factor

Advanced Network Monitoring
Built-in Ethernet network interface allows remote access for power monitoring, configuration, control and notification via web browser, SSH, telnet or SNMP
Real-time load/current data with billing-grade accuracy (+/- 1 percent)
Automated alerts help prevent accidental overloads, power loss and downtime
Optional temperature sensor (sold separately) monitors temperature and humidity

Broad Communications Compatibility
Supports HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP

20A Circuit Breakers
Protect each of 2 single-phase output banks
Front-panel LED indicates when breaker has tripped

Cord Retention Brackets
Secures equipment power cords to reduce cable clutter and increase accessibility to connected components

Mounts Horizontally in 2U of Rack Space
Compatible with EIA-standard 19 in. 4-post racks and rack enclosures

TAA-Compliant
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

This Package Includes PDUMH32HVATNET 7.4kW Single-Phase 230V ATS/Switched PDU
Rack-mounting brackets
Cord retention brackets
Cable ties
Owner’s manual

View More
In Stock: 7-10 Days
£760.22
£912.26 Inc Vat
Qty:
Other Ranges Available
Tripp Lite Switched PDUs
Tripp Lite Switched PDUs
View Range
Tripp Lite HotSwap PDUs
Tripp Lite HotSwap PDUs
View Range
Tripp Lite Basic PDUs
Tripp Lite Basic PDUs
View Range
Tripp Lite Metered PDUs
Tripp Lite Metered PDUs
View Range
Join Our Mailing List
 
Social Links
  • Apply for Credit