Product Code: | |
Options: | |
Qty: | |
Unit Price: | £ |
![]() |
High-performance On-line security for priority systems
Salicru's SLC TWIN RT2 UPS range is a highly advanced continuity solution for the electrical protection of critical systems. It combines the most reliable double-conversion technology (AC/DC-DC/AC) on the market and boasts a unity output power factor (VA=W) to enable it to power systems with high energy requirements, while offering high operating efficiency.
With a 1500 VA power rating, the SLC 1500 TWIN RT2 comes in a 2U rack format, convertible to tower format, with a swivel mount LCD display, according to the needs of the facility. Also available are solutions with an extra charger and additional battery modules for applications that require greater backup.
In terms of communications, it features an RS-232/USB interface (compatible with HID protocol) and a smart slot that can optionally hold an SNMP card, MODBUS or potential free contacts; also available are software packages for local or virtual monitoring and management of protected devices. Other outstanding features include: 50/60 or 60/50 Hz frequency converter, emergency stop (EPO) and programmable outputs for critical/non-critical loads.
Features
Applications
Salicru's SLC TWIN RT2 series offers, in a compact format, all of the necessary features for the protection of applications that require a high level of security in the event of any type of electrical disturbance, such as IT servers, voice and data networks, CAD/ CAM, document management, unified communications (UC) and video streaming.
ConnectionsMaximum Performance In Eco Mode
With performance of up to 97%, a significant energy saving can be achieved without reducing reliability and security in the protection of critical loads.
Higher Power Density
With a unity output power factor, maximum power in watts (W) is delivered, thereby optimising the always limited space in racks or server rooms.
Easy To Install / Easy To Operate
Convertible tower/rack thanks to the accessories included (rack handles, tower pedestal), swivel mount display. Intuitive LCD for operation and configuration, with optical and audible warning devices. Easy segmentation of sockets between critical/non-critical loads.
Technical Specification
MODEL | SLC 1500 TWIN PRO2 | ||
UPS Power (VA / W) | 1500 / 1500 | ||
Technology | On-line double-conversion | ||
Format | Convertible tower/rack | ||
Input | Rated Voltage | 200 / 208 / 220 / 230 / 240 V (1) | |
Voltage range | 110 - 300 V up to 60% load | ||
Total harmonic distortion (THDi) | <5% | ||
Frequency | 50 / 60 Hz ±10% | ||
Output | Rated voltage | 200/ 208 / 220 / 230 / 240 V (1) | |
Voltage accuracy (battery mode) | ±1% | ||
Power factor | 1 | ||
Total harmonic distortion (THDv) | ≤2% linear load; ≤4% non-linear load |
||
Performance | Normal mode | ≥ 89 - 91% | |
ECO mode | ≥ 95 - 97% | ||
Permissible overloads (normal mode) |
Up to 130% for 5 min; 140% for 30 s |
||
Parallel | No | ||
Synchronisation | with mains | ±3 Hz | |
without mains | ±0.1 Hz | ||
Programmable priority outputs | Yes, for critical / non-critical loads (4/4) | ||
Battery | Battery type | Pb-Ca sealed, AGM, maintenance-free | |
Protection | Against power surges, undervoltages and alternating current components | ||
Charging | Charge type | I/U (constant current/constant voltage) | |
Recharge time | 3 hours to 95% | ||
Temperature voltage compensation | Yes | ||
Communication | Interface | USB, RS-232 | |
Smart slot for SNMP / potential-free contacts / MODBUS | Yes | ||
Downloadable monitoring software | For Windows, Linux and Mac | ||
Other Functions | Emergency stop (EPO) | Yes | |
Frequency converter | Yes (2) | ||
Cold start | Yes | ||
ADSL/fax/modem transient protector | Yes | ||
General | Operating temperature | 0ºC - 40ºC | |
Relative humidity | Up to 95%, non-condensing | ||
Noise level at 1 metre | Less 50-55 dB | ||
Dimensions (D x W x H mm) | 410 x 438 x 88 (2U) | ||
Weight | 15.50Kg | ||
Standards | Safety | EN 62040-1:2008 | |
Electromagnetic compatibility (EMC) | EN 62040-2:2006(C2) | ||
Operation | EN 62040-3:2011 | ||
Quality & Environmental Management | ISO-9001 and ISO-14001 |
Salicru's SLC TWIN RT2 UPS range is a highly advanced continuity solution for the electrical protection of critical systems. It combines the most reliable double-conversion technology (AC/DC-DC/AC) on the market and boasts a unity output power factor (VA=W) to enable it to power systems with high energy requirements while offering high operating efficiency.
With a 1500 VA power rating, the SLC 1500 TWIN RT2 comes in a 2U rack format, convertible to tower format, with a swivel mount LCD display, according to the needs of the facility. Also available are solutions with an extra charger and additional battery modules for applications that require greater backup.
In terms of communications, it features an RS-232/USB interface (compatible with HID protocol) and a smart slot that can optionally hold an SNMP card, MODBUS or potential-free contacts; also available are software packages for local or virtual monitoring and management of protected devices. Other outstanding features include 50/60 or 60/50 Hz frequency converter, emergency stop (EPO) and programmable outputs for critical/non-critical loads.
Salicru's SLC TWIN RT2 series offers, in a compact format, all of the necessary features for the protection of applications that require a high level of security in the event of any type of electrical disturbance, such as IT servers, voice and data networks, CAD/ CAM, document management, unified communications (UC) and video streaming.
With performance of up to 97%, a significant energy saving can be achieved without reducing reliability and security in the protection of critical loads.
With a unity output power factor, maximum power in watts (W) is delivered, thereby optimising the always limited space in racks or server rooms.
Convertible tower/rack thanks to the accessories included (rack handles, tower pedestal), swivel mount display. Intuitive LCD for operation and configuration, with optical and audible warning devices. Easy segmentation of sockets between critical/non-critical loads.