Upgradeable Switched Unit Level Monitored EC rPDUs provide reliable power distribution to critical IT equipment while delivering individual outlet level control and a comprehensive view of input power usage via remote network access. Includes environmental monitoring capabilities to obtain real-time environmental metrics.
Upgrade the hot-swappable monitoring device on select units to leverage new technologies and accommodate changing business needs.
Product Summary
rPDU, Switched Outlet Level Monitoring EC, 16A, 230/400V WYE, 11.0kW, Horizontal, (12) Combination C13/C19, 10ft / 3m power cord with 3P+N+E (IP44), Black Powder Coat.
Key Benefits
Remotely reboot outlets to power cycle unresponsive IT equipment or increase runtime of critical equipment upon power failure with outlet-level control.
Reliable power distribution with local and remote power monitoring options offer quick access to critical power usage information to evaluate energy usage trends and maximize uptime.
Environmental monitoring capabilities with the addition of optional environmental sensors ensure users have critical infrastructure data at their fingertips to prevent climate-related equipment failure and system downtime.
Fault-Tolerant Daisy Chaining with RSTP simplifies intelligent rPDU connectivity and ensures data is reported even when a break in the network chain occurs. Supports up to 40 rPDUs.
Gather comprehensive power data at the palm of your hand with the use of the Vertiv VLC mobile app.
This product comes with a limited three-year warranty that is automatically extended to five years if the product is registered within 120 days of purchase.
Brief Product Specification
Monitoring
Input power monitoring with Outlet switching. Circuit/Breaker current monitoring. Environmental monitoring via optional remote sensors. Daisy chain Ethernet connectivity. Local high visibility LED display.
Input Monitoring
Total Unit Monitoring (kWh, W, VA, PF)
Phase (A, B, C) Monitoring (kWh, W, VA, PF, V, A)
Power Measurements Compliant with ANSI C12.1 and IEC 62053-21 at 1% Accuracy Class Requirements
Circuit Monitoring
Circuit / Breaker Monitoring (A)
Power Measurements Compliant with ANSI C12.1 and IEC 62053-21 at 1% Accuracy Class Requirements.
Remote Power Management
Individual Outlet Switching with Optional User Defined Time Delays and Sequential Power-up
Voltage
200-240/346-415V WYE
Current
32A x 3 Phase WYE
Plug Type
IEC60309 3P + N + E, 32A, 230/400V, Splashproof IP44
Receptacle/Socket Type
Combination C13/C19