Product Code: | |
Options: | |
Qty: | |
Unit Price: | £ |
Upgradeable Switched Unit Level Monitored EC rPDUs provide reliable power distribution to critical IT equipment while delivering individual outlet level control and a comprehensive view of input power usage via remote network access.
Includes environmental monitoring capabilities to obtain real-time environmental metrics. Upgrade the hot-swappable monitoring device on select units to leverage new technologies and accommodate changing business needs.
Benefits
Vertiv Geist VP5G9002 rPDU Specifications
Input Monitoring |
Total Unit Monitoring (kWh, W, VA, PF)
Phase (A, B, C) Monitoring (kWh, W, VA, PF, V, A) Power Measurements Compliant with ANSI C12.1 and IEC 62053-21 at 1% Accuracy Class Requirements |
Residual Current Metering (RCM) |
Phase (A, B, C)
Type B (AC/DC) with operating characteristics defined in IEC 62020:1998+AMD1:2003 |
Remote Power Management | Individual Outlet Switching with Optional User Defined Time Delays and Sequential Power-up |
Voltage (V) | 200-240/346-415V WYE |
Current (A) | 32A x 3 Phase WYE |
VA per Input (Load Capacity) | 22.0kW (230V) |
Input Type | (1) IEC60309 3P + N + E, 32A, 230/400V, Splashproof IP44 |
Output Type | (36) Combination C13/C19 |
Cable Length | 10ft / 3m |
Complete specifications for this PDU can be found in the documentation tab above |
Upgradeable Switched Unit Level Monitored EC rPDUs provide reliable power distribution to critical IT equipment while delivering individual outlet level control and a comprehensive view of input power usage via remote network access.
Includes environmental monitoring capabilities to obtain real-time environmental metrics. Upgrade the hot-swappable monitoring device on select units to leverage new technologies and accommodate changing business needs.
Benefits
Vertiv Geist VP5G9002 rPDU Specifications
Input Monitoring |
Total Unit Monitoring (kWh, W, VA, PF)
Phase (A, B, C) Monitoring (kWh, W, VA, PF, V, A) Power Measurements Compliant with ANSI C12.1 and IEC 62053-21 at 1% Accuracy Class Requirements |
Residual Current Metering (RCM) |
Phase (A, B, C)
Type B (AC/DC) with operating characteristics defined in IEC 62020:1998+AMD1:2003 |
Remote Power Management | Individual Outlet Switching with Optional User Defined Time Delays and Sequential Power-up |
Voltage (V) | 200-240/346-415V WYE |
Current (A) | 32A x 3 Phase WYE |
VA per Input (Load Capacity) | 22.0kW (230V) |
Input Type | (1) IEC60309 3P + N + E, 32A, 230/400V, Splashproof IP44 |
Output Type | (36) Combination C13/C19 |
Cable Length | 10ft / 3m |
Complete specifications for this PDU can be found in the documentation tab above |