Easter Bank Holiday Weekend
Early Closing Thursday

We will be closing early on Thursday 28th March at 16:30

Last orders: 16:00 (next day: 15:30) | CLOSED - Good Friday & Easter Monday

Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Login
loading Gif
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Comms Express Finance Options
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Browse Categories
Spend £100.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Austin Hughes MiniBoot - IEC Outlets, C20 Inlet
Austin Hughes Logo
Reboot & Monitor Your Device Over IP



Remote power reboot and monitoring functions are essential for hardware systems. MiniBoot Web Power Reboot & Monitoring device offers a cost-efficient power solution for any environment with electronic devices or systems. Users can try to recover the crashed device by remote reboot, reducing the need to send engineers to site (less personnel and travel costs by negating the need for staff to be at the equipment location) therefore improving uptime and productivity.

Remote Reboot & Amp Monitoring Over IP

Remote power management helps reducing manpower and hence improving uptime and productivity. It also benefits users with capacity planning and increasing the overall efficiency of the power management. MiniBoot offers two remote power management solutions for users’ selection.

Key Features

Remote Reboot to Recover Your Device

When a complete restart is required MiniBoot provides a simple and easy way to reboot a hardware device.
In addition to manual on/off, MiniBoot provides 3 kinds of auto outlet control:
IP-Ping automatically detects a failed system for timely reboot
Outlet on/off by sensor condition
Outlet on/off scheduling
Enterprise level IP Authentication

Active Directory (AD), Lightweight Directory Access Protocol (LDAPv3 / LDAPS).
Remote Access Dial-In User Service (RADIUS) protocol, or local credential database.
Strong passwords and granular user/user group permissions.
Support high-speed network IP via 1000Base-T (Gigabit) Ethernet port
Diversified Outlets & Inlets

Variety of outlets & inlets available for different regional power requirements
Outlet : US NEMA, IEC C13, UK BS1363, German Schuko CEE 7/3 or French CEE 7/5
Inlet : C20 for different regional power cords (Custom inlet available on request.)
Save Manpower & Travel Costs

Restart the problem device by remotely power on & off, MiniBoot allow user to recover the equipment via network IP.
Reduce manpower and travel costs by negating the need for staff to actually be at the equipment location, improving uptime and productivity.
Remote Management

Simultaneous access via free management web GUI.
SNMPv1/v2 & SNMPv3 for integration to DCIM.
Remote management protocols: HTTP(S); SSH Command Line Interface; Telnet; SMTP; IPv6/IPv4.
Alerts / Alarms

Receive alerts via SNMP, email (SMTP), and syslog when predefined thresholds are exceeded for both MiniBoot and environmental sensor events.
Common SNMP MIBs (Management Information Base) for all MiniBoot models.
Power Monitoring via Network & Local Meter

Allows remote monitoring via the free Graphic User Interface (GUI).
Provides local current monitoring via MiniBoot blue LED ammeter.
Allows user to establish the remaining capacity prior to adding a new device to the MiniBoot, plus displays the current being drawn and receives threshold alerts remotely.
Sensors & Wi-Fi

Variety of optional sensors: Temperature & Humidity, Temperature, Smoke, Door.
Option to connect via a WiFi kit (IPD-WIFI) complying with 802.11 g/n/ac.
Product Layout

(4 IEC Outlet Example Shown)

Single Feed MiniBoot

1  RMS current meter

2  Sensor port x 2

3  Serial port x 1

4  1000Base-T ( Gigabit ) IP port x 1

5  USB Wifi port x 1

6  C13 Switched outlets

7  C20 Inlet (Custom inlet available on request)

8  Resettable fuse

Applications

Unlike a rack PDU which is mounted inside an IT server rack enclosure, MiniBoot can be applied in diversified applications. MiniBoot is designed for a variety of industries – Transportation (Air, Land and Sea), Broadcasting, Entertainment, Advertising, Manufacturing, Mining, Satellite, Defense, Education, Telecommunication, Finance & Banking, Commercial, etc.

Commercial Offices
Telecommunication Offices
Satellite Stations
Digital Signage
Video Walls
Service Centers ATM Machines
Shopping Mall Kiosks
Airport Check-in Kiosks
Transportation Ticketing System
Vending Machines
Information Desks Factory Automation Systems
Production Plants
Assembly Line
Quality & Control Line Universities
Education Institutes
Lecture Theatres
Tutorial Classes
Training Rooms

Express View Logo
Fuse:
Outlets:
In Stock: 7-10 Days
£526.00
£631.20 Inc Vat
Add To Cart
Austin Hughes MiniBoot - 4 UK Outlets, C20 Inlet
Austin Hughes Logo



Remote power reboot and monitoring functions are essential for hardware systems. MiniBoot Web Power Reboot & Monitoring device offers a cost-efficient power solution for any environment with electronic devices or systems. Users can try to recover the crashed device by remote reboot, reducing the need to send engineers to site (less personnel and travel costs by negating the need for staff to be at the equipment location) therefore improving uptime and productivity.

Remote Reboot & Amp Monitoring Over IP

Remote power management helps reducing manpower and hence improving uptime and productivity. It also benefits users with capacity planning and increasing the overall efficiency of the power management. MiniBoot offers two remote power management solutions for users’ selection.

Key Features

Remote Reboot to Recover Your Device

When a complete restart is required MiniBoot provides a simple and easy way to reboot a hardware device.
In addition to manual on/off, MiniBoot provides 3 kinds of auto outlet control:
IP-Ping automatically detects a failed system for timely reboot
Outlet on/off by sensor condition
Outlet on/off scheduling
Enterprise level IP Authentication

Active Directory (AD), Lightweight Directory Access Protocol (LDAPv3 / LDAPS).
Remote Access Dial-In User Service (RADIUS) protocol, or local credential database.
Strong passwords and granular user/user group permissions.
Support high-speed network IP via 1000Base-T (Gigabit) Ethernet port
Diversified Outlets & Inlets

Variety of outlets & inlets available for different regional power requirements
Outlet : US NEMA, IEC C13, UK BS1363, German Schuko CEE 7/3 or French CEE 7/5
Inlet : C20 for different regional power cords (Custom inlet available on request.)
Save Manpower & Travel Costs

Restart the problem device by remotely power on & off, MiniBoot allow user to recover the equipment via network IP.
Reduce manpower and travel costs by negating the need for staff to actually be at the equipment location, improving uptime and productivity.
Remote Management

Simultaneous access via free management web GUI.
SNMPv1/v2 & SNMPv3 for integration to DCIM.
Remote management protocols: HTTP(S); SSH Command Line Interface; Telnet; SMTP; IPv6/IPv4.
Alerts / Alarms

Receive alerts via SNMP, email (SMTP), and syslog when predefined thresholds are exceeded for both MiniBoot and environmental sensor events.
Common SNMP MIBs (Management Information Base) for all MiniBoot models.
Power Monitoring via Network & Local Meter

Allows remote monitoring via the free Graphic User Interface (GUI).
Provides local current monitoring via MiniBoot blue LED ammeter.
Allows user to establish the remaining capacity prior to adding a new device to the MiniBoot, plus displays the current being drawn and receives threshold alerts remotely.
Sensors & Wi-Fi

Variety of optional sensors: Temperature & Humidity, Temperature, Smoke, Door.
Option to connect via a WiFi kit (IPD-WIFI) complying with 802.11 g/n/ac.
Product Layout

(4 UK Outlet Example Shown)

Single Feed MiniBoot

1  RMS current meter

2  Sensor port x 2

3  Serial port x 1

4  1000Base-T ( Gigabit ) IP port x 1

5  USB Wifi port x 1

6  UK outlets

7  C20 Inlet (Custom inlet available on request)

8  Resettable fuse

Applications

Unlike a rack PDU which is mounted inside an IT server rack enclosure, MiniBoot can be applied in diversified applications. MiniBoot is designed for a variety of industries – Transportation (Air, Land and Sea), Broadcasting, Entertainment, Advertising, Manufacturing, Mining, Satellite, Defense, Education, Telecommunication, Finance & Banking, Commercial, etc.

Commercial Offices
Telecommunication Offices
Satellite Stations
Digital Signage
Video Walls
Service Centers ATM Machines
Shopping Mall Kiosks
Airport Check-in Kiosks
Transportation Ticketing System
Vending Machines
Information Desks Factory Automation Systems
Production Plants
Assembly Line
Quality & Control Line Universities
Education Institutes
Lecture Theatres
Tutorial Classes
Training Rooms

Express View Logo
Fuse:
In Stock: 7-10 Days
£640.00
£768.00 Inc Vat
Add To Cart
Other Ranges Available
DataProbe
View Range
Join Our Mailing List
Social Links
  • Apply for Credit