Hi there! Our website may store cookies on your computer in order to give you
the best experience, such as remembering the items in your cart so you
can continue shopping where you left off.
By continuing to use our site, you give consent for cookies to be used.
Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface.
Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware.
PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.
Key Features
16/20A 200/208/230/240V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 16A continuous)
C20 inlet; 8.5 ft. / 2.6m C20 power cable with L6-20P plug adapter
In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
DHCP/Manual configuration support
10/100 Mbps auto-sensing
Real-time clock backup maintains the time of day and date even if the PDU is unpowered
Tiered access privileges allow an administrator and a guest to login via web browser
Alert notifications via email or SNMP traps offer immediate event notification
Fully compatible with FREE PowerAlert Network Management System / NMS Software
Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats
Mounting ears are reversible for front or rear facing rackmount installation
Included cord retention brackets
Compliant with the Federal Trade Agreements Act(TAA) for GSA Schedule purchases
This Package Includes
Rackmount PDU
Rack mounting brackets
Overview
Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.
Built-in LX Platform network management interface card. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
Features
16/20A 208/230/240V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 16A continuous)
C20 inlet; 8.5 ft. / 2.6m C20 power cable with L6-20P plug adapter
8 switched C13 outlets
1U horizontal rackmount form factor
Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets
Network interface provides PDU control and data regarding input voltage, frequency and loading information
Digital display reports load level information in amps
Auto Probe feature (Firmware 15.5.2 and greater) checks the connectivity status of any networked device and automatically takes one or more user-configured actions if the device fails to respond; actions include outlet reboot, set SNMP traps, SNMP OID sets, and even script execution when used in conjunction with the Tripp Lite PowerAlert Network Shutdown Agent (PANSA).
Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats
Mounting ears are reversible for front or rear facing rackmount installation
Included cord retention brackets
Compliant with the Federal Trade Agreements Act(TAA) for GSA Schedule purchases
Package Includes
PDUMH20HVNET Switched PDU
Rack mounting hardware
(8) Plug-lock inserts
Cord retainer
Configuration cable
(1) IEC C19-to-C20 AC Interconnection cable
IEC C19-to-L6-20P plug adapter
Owners' Manuals
Product data is provided by Icecat, we do not warrant the accuracy of the material above.
Email product to a friend Print product details
View Keywording:
X
Perfect Pairings With Your Product
Due to the size, weight and delicate nature of Data and Server Cabinets, specialist couriers are required so they arrive on site in pristine condition.
We do our utmost to bare the delivery costs meaning we can deliver your cabinet free of charge to most areas, unfortunately there are some areas of the UK we are charged a lot more to deliver to and whilst we absorb as much of this cost as we viably can in certain cases we have to pass on some of these costs. Below is a list of these areas and the additional costs of delivery per cabinet.