Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty!
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Spend £50.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Browse Categories
In Stock: 5-7 Days
£931.20
£1117.44 Inc VAT
Earn 465 Data Points when purchasing this product. More Info

Legrand 311335 KEOR DK 2000VA Internal Batteries

by Legrand
See more product details
Part No:LEG311335
Manufacturer No:311335
Delivery: In Stock: 5-7 Days
Feefo logo

/assets/images/gallery/large/1768556715LEG311335_1.jpg

Legrand 311335 KEOR DK 2000VA Internal Batteries
More Related Items
Click to change options
Colour:
Apply
£124.00 Ex VAT
Qty:
Click to change options
Colour:
Apply
£99.00 Ex VAT
Qty:
Email product to a friend
X
  • Scroll to top

    The Legrand Keor DK UPS is a high-performance, double conversion on-line uninterruptible power supply designed to deliver stable and continuous power for critical IT, network, and industrial applications. Built with high-frequency PWM technology and a solid neutral configuration, this 2000 VA / 2000 W system ensures consistent power quality, compact rack integration, and dependable energy protection within just two rack units.


    Key Features of Legrand Keor DK UPS

    • Double Conversion On-Line UPS technology for continuous power conditioning
    • Rated power of 2000 VA / 2000 W with power factor 1
    • High-frequency PWM technology for efficient operation
    • Integrated VRLA accumulator batteries housed within the UPS
    • Compact 2U rack-mount design with electronics and batteries combined
    • USB, RS-232, and SNMP interfaces for advanced monitoring
    • High efficiency up to 92.5%, with 98.3% efficiency in eco-mode

    Power Architecture

    The Keor DK utilizes true double conversion on-line technology to isolate connected equipment from electrical disturbances. With single-phase input and output, it delivers clean AC power with a maximum output voltage distortion of just 3% under linear loads.


    Input and Output Performance

    Designed to operate across a wide input voltage range of 110–280 V and input frequency range of 45–65 Hz, the system maintains stable output between 200–240 V at 50–60 Hz. This flexibility ensures reliable operation even in unstable power environments.


    Efficiency and Power Factor

    With an output power factor of 1, the UPS provides full usable power without derating. Overall system efficiency reaches 92.5% during normal operation, while eco-mode increases efficiency to 98.3%, reducing energy consumption and heat generation.


    Battery System

    The UPS includes a built-in VRLA rechargeable accumulator battery pack consisting of six single elements. The hermetically sealed batteries are housed internally, providing reliable backup power while maintaining a compact and service-friendly design.


    Connectivity and Management

    Integrated USB, RS-232, and SNMP communication interfaces enable seamless integration with network management systems. The UPS supports auto shutdown functionality and includes a potential-free switch contact for enhanced system control.


    Physical Design

    Housed in a robust IP20-rated enclosure, the Keor DK measures 88 mm in height, 440 mm in width, and 640 mm in depth. Weighing 24.4 kg, it is optimized for standard rack installations while maintaining low acoustic output at just 45 dB.


    Operating Conditions

    The UPS is engineered for operation in temperatures ranging from 0°C to 40°C, with storage capability between -10°C and 50°C. Its universal load compatibility makes it suitable for a wide range of professional power protection scenarios.

    The Legrand Keor DK UPS is a high-performance, double conversion on-line uninterruptible power supply designed to deliver stable and continuous power for critical IT, network, and industrial applications. Built with high-frequency PWM technology and a solid neutral configuration, this 2000 VA / 2000 W system ensures consistent power quality, compact rack integration, and dependable energy protection within just two rack units.


    Key Features of Legrand Keor DK UPS

    • Double Conversion On-Line UPS technology for continuous power conditioning
    • Rated power of 2000 VA / 2000 W with power factor 1
    • High-frequency PWM technology for efficient operation
    • Integrated VRLA accumulator batteries housed within the UPS
    • Compact 2U rack-mount design with electronics and batteries combined
    • USB, RS-232, and SNMP interfaces for advanced monitoring
    • High efficiency up to 92.5%, with 98.3% efficiency in eco-mode

    Power Architecture

    The Keor DK utilizes true double conversion on-line technology to isolate connected equipment from electrical disturbances. With single-phase input and output, it delivers clean AC power with a maximum output voltage distortion of just 3% under linear loads.


    Input and Output Performance

    Designed to operate across a wide input voltage range of 110–280 V and input frequency range of 45–65 Hz, the system maintains stable output between 200–240 V at 50–60 Hz. This flexibility ensures reliable operation even in unstable power environments.


    Efficiency and Power Factor

    With an output power factor of 1, the UPS provides full usable power without derating. Overall system efficiency reaches 92.5% during normal operation, while eco-mode increases efficiency to 98.3%, reducing energy consumption and heat generation.


    Battery System

    The UPS includes a built-in VRLA rechargeable accumulator battery pack consisting of six single elements. The hermetically sealed batteries are housed internally, providing reliable backup power while maintaining a compact and service-friendly design.


    Connectivity and Management

    Integrated USB, RS-232, and SNMP communication interfaces enable seamless integration with network management systems. The UPS supports auto shutdown functionality and includes a potential-free switch contact for enhanced system control.


    Physical Design

    Housed in a robust IP20-rated enclosure, the Keor DK measures 88 mm in height, 440 mm in width, and 640 mm in depth. Weighing 24.4 kg, it is optimized for standard rack installations while maintaining low acoustic output at just 45 dB.


    Operating Conditions

    The UPS is engineered for operation in temperatures ranging from 0°C to 40°C, with storage capability between -10°C and 50°C. Its universal load compatibility makes it suitable for a wide range of professional power protection scenarios.

    Product data is provided by Icecat, we do not warrant the accuracy of the material above.