Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Login
loading Gif
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Comms Express Finance Options
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Spend £100.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Browse Categories
In Stock: 2-3 Weeks
£389.86
£467.83 Inc VAT
Earn 194 Data Points when purchasing this product. More Info

/assets/images/gallery/large/1673265261FEHCINT150SL_1.jpg

Tripp Lite HCINT150SL 150W Power Inverter for Mobile Medical Equipment 230V

Tripp Lite HCINT150SL 150W Power Inverter for Mobile Medical Equipment 230V

IEC 60601-1

by Tripp Lite
See more product details
Part No:FEHCINT150SL
Manufacturer No:HCINT150SL
Delivery: In Stock: 2-3 Weeks

/assets/images/gallery/large/1673265261FEHCINT150SL_1.jpg

Tripp Lite HCINT150SL 150W Power Inverter for Mobile Medical Equipment 230V
More Related Items
Click to change options
No. Sockets:
Input Type:
Surge Protect:
Apply
£24.00 Ex VAT
Qty:
Click to change options
Length:
Fibre Size:
Apply
£4.77 Ex VAT
Qty:
Email product to a friend
X
  • Scroll to top
    Tripp Lite HCINT150SL 150W Power Inverter for Mobile Medical Equipment 230V
    IEC 60601-1

    Product Features


    150W 230V Medical-Grade Mobile Power Inverter/Charger for Medical Carts

    This cost-effective hospital-cart power inverter/charger for medical equipment integrates seamlessly into your existing system.
    The HCINT150SL medical inverter battery charger is the ideal solution for providing safe, compliant power to mobile medical equipment used both inside and outside patient care areas.

    Smart Charging System for Long Battery Life

    The advanced three-stage charger recharges batteries faster and more safely than conventional chargers.
    An internal automatic transfer switch (ATS) lets the module power connected equipment while also recharging the battery at the same time. The HCINT150SL can provide multiple hours of AC power in standard configuration, though runtime varies depending on battery condition and load.

    Superior Design for Simple Fuss-Free Use

    The HCINT150SL’s simple cart and fleet management lets you track usage data at a glance.
    Tripp Lite’s free downloadable PowerAlert software automatically saves valuable patient data from loss or corruption if the cart is left unattended and battery power is depleted.
    The included USB cable connects the module to any cart-mounted thin client or laptop computer.
    An optional remote user interface (RUI; sold separately) displays output and battery status and includes on/off and alarm-mute switches.

    Medical Inverter Provides IEC 60601-1 Compliance for All Connected Electronic Devices

    An isolation transformer reduces the cumulative shock potential of connected equipment, which helps ensure IEC 60601-1 compliance for use in every sector of healthcare facilities, including patient care areas.
    This unit is compatible with both sealed lead acid (SLA) and Lithium Ion Phosphate (LiFePhos) batteries, so you can determine which technology best fits your needs. In addition to IEC 60601-1, this module meets NFPA, NEC and JCAHO standards.

    Combats Electromagnetic Interference That Can Harm Equipment

    Various electromagnetic and radio sources found in virtually every medical facility can cause disruptive interference on the AC line. Known as EMI (electromagnetic interference) and
    RFI (radio frequency interference), this line noise is a common cause of performance problems and can lead to incremental hardware damage and data corruption.
    The HCINT150SL incorporates technology that filters out disruptive line noise so that it won’t affect your equipment.

    Rugged Construction Sure to Stand Up to Demanding Environments

    The compact steel housing features a USB communication port and one C13 AC outlet on a six-inch dongle for connecting a device’s power cord.
    It is designed to endure in severe medical environments where reliable power is essential.

    Product Features

    All-in-one inverter/charger/controller powers equipment on mobile medical carts

    IEC 60601-1 compliance for use inside and outside patient care areas

    Approved to IEC60601-1-2:2014, 4th Ed.

    Works with both SLA and LiFePhos batteries to best fit your power requirements

    Internal ATS powers connected equipment and recharges battery simultaneously

    Free PowerAlert® software protects valuable patient data from loss or corruption

    2-year limited warranty

    Product Features


    150W 230V Medical-Grade Mobile Power Inverter/Charger for Medical Carts

    This cost-effective hospital-cart power inverter/charger for medical equipment integrates seamlessly into your existing system.
    The HCINT150SL medical inverter battery charger is the ideal solution for providing safe, compliant power to mobile medical equipment used both inside and outside patient care areas.

    Smart Charging System for Long Battery Life

    The advanced three-stage charger recharges batteries faster and more safely than conventional chargers.
    An internal automatic transfer switch (ATS) lets the module power connected equipment while also recharging the battery at the same time. The HCINT150SL can provide multiple hours of AC power in standard configuration, though runtime varies depending on battery condition and load.

    Superior Design for Simple Fuss-Free Use

    The HCINT150SL’s simple cart and fleet management lets you track usage data at a glance.
    Tripp Lite’s free downloadable PowerAlert software automatically saves valuable patient data from loss or corruption if the cart is left unattended and battery power is depleted.
    The included USB cable connects the module to any cart-mounted thin client or laptop computer.
    An optional remote user interface (RUI; sold separately) displays output and battery status and includes on/off and alarm-mute switches.

    Medical Inverter Provides IEC 60601-1 Compliance for All Connected Electronic Devices

    An isolation transformer reduces the cumulative shock potential of connected equipment, which helps ensure IEC 60601-1 compliance for use in every sector of healthcare facilities, including patient care areas.
    This unit is compatible with both sealed lead acid (SLA) and Lithium Ion Phosphate (LiFePhos) batteries, so you can determine which technology best fits your needs. In addition to IEC 60601-1, this module meets NFPA, NEC and JCAHO standards.

    Combats Electromagnetic Interference That Can Harm Equipment

    Various electromagnetic and radio sources found in virtually every medical facility can cause disruptive interference on the AC line. Known as EMI (electromagnetic interference) and
    RFI (radio frequency interference), this line noise is a common cause of performance problems and can lead to incremental hardware damage and data corruption.
    The HCINT150SL incorporates technology that filters out disruptive line noise so that it won’t affect your equipment.

    Rugged Construction Sure to Stand Up to Demanding Environments

    The compact steel housing features a USB communication port and one C13 AC outlet on a six-inch dongle for connecting a device’s power cord.
    It is designed to endure in severe medical environments where reliable power is essential.

    Product Features

    All-in-one inverter/charger/controller powers equipment on mobile medical carts

    IEC 60601-1 compliance for use inside and outside patient care areas

    Approved to IEC60601-1-2:2014, 4th Ed.

    Works with both SLA and LiFePhos batteries to best fit your power requirements

    Internal ATS powers connected equipment and recharges battery simultaneously

    Free PowerAlert® software protects valuable patient data from loss or corruption

    2-year limited warranty

    Email product to a friend
    Print product details
    View Keywording: