Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Login
loading Gif
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Comms Express Finance Options
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Spend £100.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Browse Categories
In Stock: 2-3 Weeks
£2368.71
£2842.45 Inc VAT
Earn 1184 Data Points when purchasing this product. More Info

/assets/images/gallery/large/1560937743salicru-twinRT-1-large.png

Salicru 698RQ000003 5kVA Online Rackmount UPS

Salicru 698RQ000003 5kVA Online Rackmount UPS

Standard Model

by Salicru
See more product details
Part No:FE698RQ000003
Manufacturer No:698RQ000003
Delivery: In Stock: 2-3 Weeks
5000-6000Va
5000-6000Va
Battery Extendable
Battery Extendable
Network Manageable
Network Manageable
Online
Online

/assets/images/gallery/large/1560937743salicru-twinRT-1-large.png

Salicru 698RQ000003 5kVA Online Rackmount UPS
More Related Items
Email product to a friend
X
  • Scroll to top
    Salicru 698RQ000003 5kVA Online Rackmount UPS
    Standard Model

    High-performance On-line security for priority systems

    Salicru's SLC TWIN RT2 UPS range is a highly advanced continuity solution for the electrical protection of critical systems. It combines the most reliable double-conversion technology (AC/DC-DC/AC) on the market and boasts a unity output power factor (VA=W) to enable it to power systems with high energy requirements, while offering high operating efficiency.

    With a 5kVA power rating, the SLC 5000 TWIN RT2 comes in a 4U rack format, convertible to tower format, with a swivel mount LCD display, according to the needs of the facility. Also available are solutions with an extra charger and additional battery modules for applications that require greater backup.

    In terms of communications, it features an RS-232/USB interface and a smart slot that can optionally hold an SNMP card, MODBUS or potential free contacts; also available are software packages for local or virtual monitoring and management of protected devices. Other outstanding features include: 50/60 or 60/50 Hz frequency converter, emergency stop (EPO) and system operation in parallel (up to 3 units).

    Features

    • On-line double-conversion technology.
    • Output power factor PF=1. (Except for devices with extended backup)
    • Convertible tower/rack format.
    • Control panel with swivel mount LCD display and keypad.
    • Includes pedestal (pedestal mount) and lugs (rack mount).
    • Backup extensions available for all power ratings.
    • UPS models with extra charger for backup extensions.
    • RS-232 and USB communication interfaces.
    • Downloadable monitoring software for Windows, Linux and Mac.
    • Smart slot for SNMP/potential-free contacts/MODBUS.
    • Eco-mode operation.
    • Parallelable up to 3 units.
    • PDU strip for distribution of output loads.
    • Frequency conversion function.
    • SLC Greenergy solution.

    Applications

    Salicru's SLC TWIN RT2 series offers, in a compact format, all of the necessary features for the protection of applications that require a high level of security in the event of any type of electrical disturbance, such as IT servers, voice and data networks, CAD/ CAM, document management, unified communications (UC) and video streaming.

    Connections
    1. Current distribution port.
    2. Parallel port.
    3. Input circuit breaker.
    4. Input/output terminals.
    5. Emergency stop (EPO).
    6. USB interface.
    7. RS-232 interface.
    8. Smart slot for SNMP/potential-free contacts/ MODBUS.
    9. Emergency stop (EPO).
    10. Connection for battery module (only in models with extra charger).

    Maximum Performance In Eco Mode

    With performance of up to 99%, a significant energy saving can be achieved without reducing reliability and security in the protection of critical loads.

    Higher Power Density

    With a unity output power factor, maximum power in watts (W) is delivered, thereby optimising the always limited space in racks or server rooms.

    Easy To Install / Easy To Operate

    Convertible tower/rack thanks to the accessories included (rack handles, tower pedestal), swivel mount display. Intuitive LCD for operation and configuration, with optical and audible warning devices. Easy segmentation of sockets between critical/non-critical loads.

    Comparison Chart

    Technical Specification

    MODEL SLC 5000 TWIN PRO2
    UPS Power (VA / W) 5000 / 5000
    Technology On-line double-conversion
    Format Convertible tower/rack
    Input Rated Voltage 208 / 220 / 230 / 240 V (1)
    Voltage range 110 - 300 V up to 50% load
    Total harmonic distortion (THDi) <4%
    Frequency 50 / 60 Hz ±4%
    Output Rated voltage 208 / 220 / 230 / 240 V (1)
    Voltage accuracy (battery mode) ±1%
    Power factor 1
    Total harmonic distortion (THDv) ≤1% linear load;
    ≤4% non-linear load
    Performance Normal mode ≥ 93 - 94%
    ECO mode ≥ 99%
    Permissible overloads
    (normal mode)
    Up to 110% for 10 min;
    130% for 1 min
    Parallel Yes, up to 3 units (3)
    Synchronisation with mains ±4 Hz
    without mains ±0.1 Hz
    Programmable priority outputs No
    Battery Battery type Pb-Ca sealed, AGM, maintenance-free
    Protection Against power surges, undervoltages and alternating current components
    Charging Charge type I/U (constant current/constant voltage)
    Recharge time 7-9 hours to 90%
    Temperature voltage compensation Yes
    Communication Interface USB, RS-232 and relay
    Smart slot for SNMP / potential-free contacts / MODBUS Yes
    Downloadable monitoring software For Windows, Linux and Mac
    Other Functions Emergency stop (EPO) Yes
    Frequency converter Yes (4)
    Cold start Yes
    ADSL/fax/modem transient protector No
    General Operating temperature 0ºC - 40ºC
    Relative humidity Up to 95%, non-condensing
    Noise level at 1 metre Less 58-60 dB
    Dimensions (D x W x H mm) 2 x 600/688 x 438 x 88 (4U)
    Weight 69Kg
    Standards Safety EN 62040-1:2008
    Electromagnetic compatibility (EMC) EN 62040-2 Category C3
    Operation EN 62040-3:2011
    Quality & Environmental Management ISO-9001 and ISO-14001
    (1) Power reduction to 90% for 208 V input
    (2) Except for devices with extended backup
    (3) Power reduction to 90%
    (4) Power reduction to 60%

    With a 5kVA power rating, the SLC 5000 TWIN RT2 comes in a 4U rack format, convertible to tower format, with a swivel mount LCD display, according to the needs of the facility. Also available are solutions with an extra charger and additional battery modules for applications that require greater backup.

    In terms of communications, it features an RS-232/USB interface and a smart slot that can optionally hold an SNMP card, MODBUS or potential free contacts; also available are software packages for local or virtual monitoring and management of protected devices. Other outstanding features include: 50/60 or 60/50 Hz frequency converter, emergency stop (EPO) and system operation in parallel (up to 3 units).

    Additional Features

    • UPS models with extra charger for backup extensions.
    • RS-232 and USB communication interfaces.
    • Downloadable monitoring software for Windows, Linux and Mac.
    • Smart slot for SNMP/potential-free contacts/MODBUS.
    • Eco-mode operation.
    • Parallelable up to 3 units.
    • PDU strip for distribution of output loads.
    • Frequency conversion function.
    • SLC Greenergy solution.

    Applications

    Salicru's SLC TWIN RT2 series offers, in a compact format, all of the necessary features for the protection of applications that require a high level of security in the event of any type of electrical disturbance, such as IT servers, voice and data networks, CAD/ CAM, document management, unified communications (UC) and video streaming.

    Connections

    Connections
    1. Current distribution port.
    2. Parallel port.
    3. Input circuit breaker.
    4. Input/output terminals.
    5. Emergency stop (EPO).
    6. USB interface.
    7. RS-232 interface.
    8. Smart slot for SNMP/potential-free contacts/ MODBUS.
    9. Emergency stop (EPO).
    10. Connection for battery module (only in models with extra charger).

    Maximum Performance In Eco Mode

    With performance of up to 99%, a significant energy saving can be achieved without reducing reliability and security in the protection of critical loads.

    Higher Power Density

    With a unity output power factor, maximum power in watts (W) is delivered, thereby optimising the always limited space in racks or server rooms.

    Easy To Install / Easy To Operate

    Convertible tower/rack thanks to the accessories included (rack handles, tower pedestal), swivel mount display. Intuitive LCD for operation and configuration, with optical and audible warning devices. Easy segmentation of sockets between critical/non-critical loads.

    Email product to a friend
    Print product details
    View Keywording: