Easter Bank Holiday Weekend
Early Closing Thursday

We will be closing early on Thursday 28th March at 16:30

Last orders: 16:00 (next day: 15:30) | CLOSED - Good Friday & Easter Monday

Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Login
loading Gif
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Comms Express Finance Options
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Spend £100.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Browse Categories
In Stock: 1-2 Days
Was: £464.84
£452.09
£542.51 Inc VAT
Earn 226 Data Points when purchasing this product. More Info

/assets/images/gallery/large/SentinelDual_Large1.jpg

Riello SDH 1000 1000VA Sentinal Dual - Tower/Rack mount
scroll
to top

Riello SDH 1000 1000VA Sentinal Dual - Tower/Rack mount

with 5 minutes autonomy at full load

by Riello
See more product details
Part No:RISDH1000
Manufacturer No:SDH 1000
Delivery: In Stock: 1-2 Days

/assets/images/gallery/large/SentinelDual_Large1.jpg

Riello SDH 1000 1000VA Sentinal Dual - Tower/Rack mount
scroll
to top
Email product to a friend
X
  • Scroll to top
    Riello SDH 1000 1000VA Sentinal Dual - Tower/Rack mount
    with 5 minutes autonomy at full load
    Sentinel Dual is the new range of high density double conversion online UPS, suitable for powering a wide range of devices such as servers, storage systems, telephony - VoIP equipment, network and medical systems as well as industrial applications. It is also ideal for powering and protecting Blade Server systems with high input power factor. At only 2U, Sentinel Dual is ideal for 19” rack cabinet installations. Sentinel Dual has a practical, modern design and includes several performance advantages over traditional on-line UPS. All developed by the Riello UPS research and development team. The newly-designed inverter is one of the best energy conversion systems on the market, with a 0.9 output power factor and 92% operating efficiency in on-line mode. For business continuity applications requiring long battery runtimes, battery autonomy can be extended up to several hours using ER models fitted with more powerful battery chargers. With energy savings in mind, Sentinel Dual is also fitted with a shut-off button to reduce energy consumption to zero during prolonged periods of inactivity.



    Simplified installation
    • Sentinel Dual can be installed as a tower or in 19” rack cabinets, by simply removing and rotating the display panel
    • Low noise (
    • Operation guaranteed up to 40°C (the components are designed for high temperatures and are thus subject to less stress at normal temperatures)
    • On Sentinel Dual models, the output sockets can be programmed to disconnect less critical loads during blackouts (EnergyShare function).
    Installation versatility
    Sentinel Dual can be used in a tower or rack format, by simply turning the display and adding the supplied handles or optional runners.

    Reduced running costs
    The UPS is highly flexible and easy to configure. Programmable functions can be set via software or manually via the front display panel. Sentinel Dual can be configured in the following operating modes:
    • On Line, maximum load protection and output voltage waveform quality
    • ECO Mode, to increase efficiency (up to to 98%); allows you to select Line Interactive technology
    • Smart Active, the UPS automatically decides the operating mode based on the mains power quality
    • Emergency, the UPS can be selected to function only when the mains power supply fails (emergency only mode)
    • Frequency converter operation (50 or 60 Hz).
    Advanced communications
    Sentinel Dual offers maximum flexibility for integration with all types of communication systems.
    • Multi-platform communication for all operating systems and network environments: PowerShield3 supervision and shutdown software for Windows operating systems 10, 8, 7, Hyper-V, 2016, 2012, and previous versions, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems.
    • UPS Tools configuration and customisation software supplied as standard
    • RS232 serial port and opto-isolated contacts
    • USB port
    • Slot for communications boards such as Modbus/Jbus, TCP/IP-SNMP and relay contacts.
    Emergency function
    This configuration ensures the operation of emergency systems that must be supplied in the event of a mains power failure, such as emergency lighting, fire detection/ extinguishing systems and alarms. When the mains power supply fails, the inverter begins powering the loads with a progressive start-up (Soft Start) in order to prevent overload. Sentinel Dual is compliant for installation in medium-voltage transformer rooms in accordance with applicable legislation, for the power supply with reserve charge of medium-voltage coils.

    High quality output voltage
    • Even with non-linear loads (IT loads with a crest factor of up to 3:1)
    • High short circuit current on bypass
    • High overload capacity: 150% by inverter (even with mains failure)
    • Filtered, stabilised and reliable voltage (On-line double conversion technology (VFI compliant with EN62040-2) with filters for the suppression of atmospheric disturbances
    • Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake.
    High battery reliability
    • Automatic and manual battery test
    • Batteries are user replaceable without switching off equipment and without interruption to the load (Hot Swap)
    • Unlimited extendible runtime using matching battery boxes.
    Low noise level
    Thanks to the use of high frequency components and load-based fan speed control, the noise produced by the UPS is less than 40 dB.

    Other features
    • Output voltage can be selected via software (220-230-240 V)
    • Auto-restart when mains power is restored (programmable via software)
    • Stand-by on bypass: when the machine is switched off, it automatically goes into bypass and battery charge mode
    • Minimum load switch-off
    • Battery discharge warning
    • Start-up delay
    • Total microprocessor control
    • Automatic bypass without interruption
    • Status, measurements and alarms available on standard backlit display
    • UPS firmware updating via PC
    • Input protection via resettable thermal switch (versions up to 1500 VA)
    • Back-feed protection standard: to prevent energy from being fed back to the network
    • Manual switching to bypass
    • 2 Year Warranty
     
    USB Plug USB Plug Energy Share
    Plug & Play Installation ToweRack
    E-Medical Online 
    Industry Emergency
    SoHo Hot swap battery
    Transport Datacentre
    Eco Level 6    

    Eco Energy: efficiency level

    Riello UPS 's social commitment aims to help the present as well as shape a bright future, combining the inevitable need for energy with environmental protection.

    Riello UPS uninterruptible power supplies power some of the most critical data centres and servers in use today. Within these environments, energy management is critical. Running costs must be minimised without compromising resilience, i.e. the ability to adapt to adverse external conditions whilst ensuring the complete availability of the services provided. Equipment must operate at the highest possible levels of efficiency to reduce the strain on critical power supplies and minimise the effect on the installation area.

    Riello UPS models have always been compliant with the highest levels of efficiency in terms of energy protection and are classified according to a scale with 6 levels, corresponding with the efficiency value of the UPS with respect to the European Code of Conduct; this is known as the Eco Energy Level.




    The Eco Energy Level system demonstrates how the most efficient UPS provide energy savings that allow the cost of their purchase to be recovered quickly compared to standard efficiency UPS , as well as how their use leads to significant reductions in carbon emissions into the atmosphere.


    Simplified installation

    Simplified installation

    • Sentinel Dual can be installed as a tower or in 19” rack cabinets, by simply removing and rotating the display panel
    • Low noise (
    • Operation guaranteed up to 40°C (the components are designed for high temperatures and are thus subject to less stress at normal temperatures)
    • On Sentinel Dual models, the output sockets can be programmed to disconnect less critical loads during blackouts (EnergyShare function).

    Installation versatility
    Sentinel Dual can be used in a tower or rack format, by simply turning the display and adding the supplied handles or optional runners.

    Reduced running costs
    The UPS is highly flexible and easy to configure. Programmable functions can be set via software or manually via the front display panel. Sentinel Dual can be configured in the following operating modes:

    • On Line, maximum load protection and output voltage waveform quality
    • ECO Mode, to increase efficiency (up to to 98%); allows you to select Line Interactive technology
    • Smart Active, the UPS automatically decides the operating mode based on the mains power quality
    • Emergency, the UPS can be selected to function only when the mains power supply fails (emergency only mode)
    • Frequency converter operation (50 or 60 Hz).

    Advanced communications
    Sentinel Dual offers maximum flexibility for integration with all types of communication systems.

    • Multi-platform communication for all operating systems and network environments: PowerShield3 supervision and shutdown software for Windows operating systems 10, 8, 7, Hyper-V, 2016, 2012, and previous versions, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems.
    • UPS Tools configuration and customisation software supplied as standard
    • RS232 serial port and opto-isolated contacts
    • USB port
    • Slot for communications boards such as Modbus/Jbus, TCP/IP-SNMP and relay contacts.

    Emergency function
    This configuration ensures the operation of emergency systems that must be supplied in the event of a mains power failure, such as emergency lighting, fire detection/ extinguishing systems and alarms. When the mains power supply fails, the inverter begins powering the loads with a progressive start-up (Soft Start) in order to prevent overload. Sentinel Dual is compliant for installation in medium-voltage transformer rooms in accordance with applicable legislation, for the power supply with reserve charge of medium-voltage coils.

    High quality output voltage

    • Even with non-linear loads (IT loads with a crest factor of up to 3:1)
    • High short circuit current on bypass
    • High overload capacity: 150% by inverter (even with mains failure)
    • Filtered, stabilised and reliable voltage (On-line double conversion technology (VFI compliant with EN62040-2) with filters for the suppression of atmospheric disturbances
    • Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake.

    High battery reliability

    • Automatic and manual battery test
    • Batteries are user replaceable without switching off equipment and without interruption to the load (Hot Swap)
    • Unlimited extendible runtime using matching battery boxes.

    Low noise level
    Thanks to the use of high frequency components and load-based fan speed control, the noise produced by the UPS is less than 40 dB.


    USB Plug USB Plug
    Energy Share Energy Share
    Plug and Play Installation Plug & Play Installation
    ToweRack ToweRack
    E-Medical E-Medical
    Online Online 
    Industry Industry
    Emergency Emergency
    SoHo SoHo
    Hot swap battery Hot swap battery
    Transport Transport
    Datacentre Datacentre
    Eco Level 6 Eco Level 6

    Eco Energy: efficiency level

    Riello UPS 's social commitment aims to help the present as well as shape a bright future, combining the inevitable need for energy with environmental protection.

    Riello UPS uninterruptible power supplies power some of the most critical data centres and servers in use today. Within these environments, energy management is critical. Running costs must be minimised without compromising resilience, i.e. the ability to adapt to adverse external conditions whilst ensuring the complete availability of the services provided. Equipment must operate at the highest possible levels of efficiency to reduce the strain on critical power supplies and minimise the effect on the installation area.

    Riello UPS models have always been compliant with the highest levels of efficiency in terms of energy protection and are classified according to a scale with 6 levels, corresponding with the efficiency value of the UPS with respect to the European Code of Conduct; this is known as the Eco Energy Level.


    ECO Mode

    The Eco Energy Level system demonstrates how the most efficient UPS provide energy savings that allow the cost of their purchase to be recovered quickly compared to standard efficiency UPS , as well as how their use leads to significant reductions in carbon emissions into the atmosphere.