Early Closing Friday

We will be closing early on Friday 26th April at 17:00

Last orders: 16:30 (next day: 16:00) | OPEN as normal Monday

Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Login
loading Gif
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Comms Express Finance Options
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Spend £100.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Browse Categories
No Stock: 2-3 Weeks
£400.51
£480.61 Inc VAT
Earn 200 Data Points when purchasing this product. More Info

Triad MaxAirflow Floor Vent Tile 1360kg Load - 600mm x 600mm Grey

by Upsite Technologies
See more product details
Part No:DCCCTILE1360
Delivery: No Stock: 2-3 Weeks
More Related Items
Click to change options
Colour:
Door:
Flat Pack:
Accessory Kit:
Apply
£516.00 Ex VAT
Qty:
£97.96 Ex VAT
Qty:
Click to change options
Colour:
Apply
£1.40 Ex VAT
Qty:
Email product to a friend
X
  • Scroll to top
    Triad MaxAirflow Floor Vent Tile 1360kg Load - 600mm x 600mm Grey

    Frequently the cooled air flowing through raised floor panels does not reach servers and IT equipment at top of the server cabinets. Hardware is not cooled properly, overheats and can fail. High-plume airflow and high cold air pressure can resolve these problems. Increasing static air pressure via the CRAC units only increases energy costs and rarely gives the desired effect - pushing cold air to the top of the server racks. The result of using inefficient perforated floor tiles is enormous power consumption, ever increasing energy costs and hotspots which shorten the life of data centre hardware. There is another solution that is cost effective and efficient - CoolControl Tiles are passive perforated floor panels that have 65% airflow throughput ensuring cooler hardware and lower energy costs.

    Patented fin design with high airflow for optimum cooling and efficiency
    Conventional perforated raised floor panels achieve airflow rates of 20-30%. The CoolControl Tile achieves 65% airflow as well as directing conditioned air to the upper most levels of server racks. The higher the flow rate, the higher the volume of cold air that reaches your rack equipment. It is critical that the perforated raised floor tiles provide enough cold air via highplume stratification. Only then can the cold air reach the top of the cabinets to cool the upper most hardware. Sufficient cool air is the primary factor in preventing system failures and downtime created by overheating and hotspots. Cool-Control Tile‘s Hi-Plume Stratification Fin scoops air to the upper most servers, while ensuring middle and lower servers also receive required cooling capacity. Through this unique design server temperatures can be decreased by 3-8°C while simultaneously lowering energy consumption. In choosing the most effective
    perforated floor tiles, remember the following: The higher the airflow rate and the higher the airflow stratification the lower the required cooling capacity resulting in energy and cost savings.

    Heavy duty panels for high loads with integrated handles
    Not only does the airflow rate matter, but also the strength of the perforated floor tiles. These panels often carry heavy loads including fully loaded cabinets. Conventional perforated floor tiles barely manage to carry a maximum weight of 200 - 300kg - without tightened edges. Our CoolControl perforated raised floor panels can reliably carry between 680 and 1360kg depending on the version. Of course easy access is also required. The patent protected integrated Lift-n-Lock® handles provide safe, balanced lifting and placement of tiles without danger of trapping fingers or toes. Integrated handles eliminate the need to lift adjacent tiles to remove the vented floor tile. CoolControl Tiles can pay for themselves in nine to twelve months through higher cooling efficiency and lower energy costs. When including the longer life of hardware through the reduction of hotspots and the time it takes to replace it, the ROI is a matter of months.

    CoolControl Tiles Highlights

    • Optimised hi-plume stratification fins
    • Patent protected Lift-n-Lock handles provide safe lifting and placement
    • Airflow rate up to 65 percent
    • Protects cabinet hardware against overheatingand downtime
    • Optional dampers to reduce airflow
    • Significant reduction of energy consumption and costs
    • Ultimate load of up to 1360kg

    Overview

    Frequently the cooled air flowing through raised floor panels does not reach servers and IT equipment at top of the server cabinets. Hardware is not cooled properly, overheats and can fail. High-plume airflow and high cold air pressure can resolve these problems. Increasing static air pressure via the CRAC units only increases energy costs and rarely gives the desired effect - pushing cold air to the top of the server racks. The result of using inefficient perforated floor tiles is enormous power consumption, ever-increasing energy costs and hotspots which shorten the life of data centre hardware. There is another solution that is cost-effective and efficient - CoolControl Tiles are passive perforated floor panels that have 65% airflow throughput ensuring cooler hardware and lower energy costs.

    CoolControl Tiles Highlights

    • Optimised hi-plume stratification fins
    • Patent protected Lift-n-Lock handles provide safe lifting and placement
    • Airflow rate up to 65 percent
    • Protects cabinet hardware against overheating and downtime
    • Optional dampers to reduce airflow
    • Significant reduction of energy consumption and costs
    • Ultimate load of up to 1360kg

    Patented fin design with high airflow for optimum cooling and efficiency

    Conventional perforated raised floor panels achieve airflow rates of 20-30%. The CoolControl Tile achieves 65% airflow as well as directing conditioned air to the uppermost levels of server racks. The higher the flow rate, the higher the volume of cold air that reaches your rack equipment. It is critical that the perforated raised floor tiles provide enough cold air via high plume stratification. Only then can the cold air reach the top of the cabinets to cool the uppermost hardware. Sufficient cool air is the primary factor in preventing system failures and downtime created by overheating and hotspots. Cool-Control Tile‘s Hi-Plume Stratification Fin scoops air to the uppermost servers while ensuring middle and lower servers also receive required cooling capacity. Through this unique design, server temperatures can be decreased by 3-8°C while simultaneously lowering energy consumption. In choosing the most effective perforated floor tiles, remember the following: The higher the airflow rate and the higher the airflow stratification the lower the required cooling capacity resulting in energy and cost savings.

    Heavy-duty panels for high loads with integrated handles

    Not only does the airflow rate matter, but also the strength of the perforated floor tiles. These panels often carry heavy loads including fully loaded cabinets. Conventional perforated floor tiles barely manage to carry a maximum weight of 200 - 300kg - without tightened edges. Our CoolControl perforated raised floor panels can reliably carry between 680 and 1360kg depending on the version. Of course, easy access is also required. The patent-protected integrated Lift-n-Lock® handles provide safe, balanced lifting and placement of tiles without danger of trapping fingers or toes. Integrated handles eliminate the need to lift adjacent tiles to remove the vented floor tile. CoolControl Tiles can pay for themselves in nine to twelve months through higher cooling efficiency and lower energy costs. When including the longer life of hardware through the reduction of hotspots and the time it takes to replace it, the ROI is a matter of months.

    Email product to a friend