Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Login
loading Gif
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Comms Express Finance Options
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Spend £50.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Browse Categories
End of Life Product
£1006.56
£1207.87 Inc VAT
Earn 503 Data Points when purchasing this product. More Info
Sorry, this item is no longer available from Comms Express.

/assets/images/gallery/large/1653903492EMAB22-1.png

Eaton ePDU: Managed IEC - 0U - In: C20 16A 1P - Out C13, 20 : C19, 4

Eaton ePDU: Managed IEC - 0U - In: C20 16A 1P - Out C13, 20 : C19, 4

by Eaton
See more product details
Part No:FEEMAB22
Manufacturer No:EMAB22
Delivery: End of Life Product

/assets/images/gallery/large/1653903492EMAB22-1.png

Eaton ePDU: Managed IEC - 0U - In: C20 16A 1P - Out C13, 20 : C19, 4
More Related Items
Click to change options
Length:
Fibre Size:
Apply
£8.26 Ex VAT
Qty:
Email product to a friend
X
  • Scroll to top
    Eaton ePDU: Managed IEC - 0U - In: C20 16A 1P - Out C13, 20 : C19, 4

    Switch and meter outlets & IT equipment across A and B feed: Combines both Switched and Metered Outlet functionality together in 1 ePDU

    ePDU G3 Managed models allow complete lights-out control and metering of devices including devices powered across multiple ePDUs. They include IEC Class 1 (±1%) billing grade accuracy, an advanced hot-swap meter with LCD pixel display showing V, W, A and kWh, and the ability to daisy chain 8 ePDUs to share the same network connection and IP address.

    Features:

    • Securely allows remote control and remote rebooting
    • Allows device level metering over A and B feeds
    • Input and Phase Metering, Circuit Breaker Current Metering, circuit Breaker status monitoring
    • Level 3 PUE measurements
    • Switch and Meter Equipment on/off across both A and B feed (Requires Daisy Chained ePDUs)
    • Sequence Outlets to avoid in-rush current, to ensure equipment starts in correct order
    • Highly secure with user access control, password protection and SSL configurable to 1024 or 2048 bit
    • IEC outlet eGrip plug retention: retains all standard IEC plugs
    • 60 Degree C operating temperature
    • Colour-coded outlet and branch circuits for simple load balancing
    • Eaton Hydraulic–Magnetic Circuit Breakers with accidental trip protection
    • Low-profile form factor: 52mm wide x 53mm deep x 1604mm high
    • En masse configuration and update available via Intelligent Power Manager software
    • Single Pane Monitoring of many ePDUs+UPS as part of the power chain, & graceful Equipment shut down via Intelligent Power Manager software
    • Installation: Button mounting on rear & side + variable mounting system



    Input:- 3 metre Single-phase 230v IEC-320-C20



    Output:- 20 x IEC-320-C13





    Output:- 4 x IEC-320-C19


    Daisy Chain
    Daisy-Chain 8 ePDUs from one IP port  and one IP address: this reduces the cost  of networking, reduces IP addresses and data packets on the network. Daisy Chaining reduces network infrastructure costs by up to 87%

    Integrated Grip
    IEC Plug Retention: Prevents accidental disconnect from being bumped or from vibration. Works with any IEC plug, no  need to buy special cables or brackets.


    Easy Configuration
    includes central advanced LCD display with menu system. Change settings incl. IP address, configure via USB stick copy / paste configuration file or configure En Masse via IPM software. 


    Low profile chassis 

    The ePDU doesn’t protrude into the rack and is low profile even at the breakers
    52mm wide x 53mm high and 58.7mm at breakers on most models
    Hydraulic-Magnetic Circuit Breakers include accidental-tip protection by default








    Small with Flexible Mounting: Easily access hot-swappable IT equipment and components.


    • ePDUs are available in 0U to fit vertically on the back of a rack, or in 1U/2U to be mounted horizontally in any server rack
    • Ensure the ePDU, plugs and cables are completely out of the way of equipment with button mount on the rear and sides
    • Optionally side mount to face the rear doors of the rack to ensure the ePDU, plugs and cables don’t interfere with hot-swap IT equipment
    • Choose to raise or lower the ePDU in the rack to suit your installation
    • Unique patented variable mounting system can be mounted at any point on the ePDU and gives full flexibility

    No Downtime on Upgrades

    ePDU G3 has Hot-Swap network components - update or change without changing the outlet state






    Overview

    ePDU G3 Managed models allow complete lights-out control and metering of devices including devices powered across multiple ePDUs. They include IEC Class 1 (±1%) billing grade accuracy, an advanced hot-swap meter with LCD pixel display showing V, W, A and kWh, and the ability to daisy chain 8 ePDUs to share the same network connection and IP address.

    Features

    • Securely allows remote control and remote rebooting
    • Allows device level metering over A and B feeds
    • Input and Phase Metering, Circuit Breaker Current Metering, circuit Breaker status monitoring
    • Level 3 PUE measurements
    • Switch and Meter Equipment on/off across both A and B feed (Requires Daisy Chained ePDUs)
    • Sequence Outlets to avoid in-rush current, to ensure equipment starts in the correct order
    • Highly secure with user access control, password protection and SSL configurable to 1024 or 2048 bit
    • IEC outlet eGrip plug retention: retains all standard IEC plugs
    • 60 Degree C operating temperature
    • Colour-coded outlet and branch circuits for simple load balancing
    • Eaton Hydraulic–Magnetic Circuit Breakers with accidental trip protection
    • Low-profile form factor: 52mm wide x 53mm deep x 1604mm high
    • En masse configuration and update available via Intelligent Power Manager software
    • Single Pane Monitoring of many ePDUs+UPS as part of the power chain, & graceful Equipment shut down via Intelligent Power Manager software
    • Installation: Button mounting on rear & side + variable mounting system

    Small with Flexible Mounting: Easily access hot-swappable IT equipment and components

    • ePDUs are available in 0U to fit vertically on the back of a rack, or in 1U/2U to be mounted horizontally in any server rack
    • Ensure the ePDU, plugs and cables are completely out of the way of equipment with button mount on the rear and sides
    • Optionally side mount to face the rear doors of the rack to ensure the ePDU, plugs and cables don’t interfere with hot-swap IT equipment
    • Choose to raise or lower the ePDU in the rack to suit your installation
    • The unique patented variable mounting system can be mounted at any point on the ePDU and gives full flexibility

    Daisy Chain

    Daisy-Chain 8 ePDUs from one IP port and one IP address: this reduces the cost of networking, reduces IP addresses and data packets on the network. Daisy Chaining reduces network infrastructure costs by up to 87%.

    Integrated Grip

    IEC Plug Retention: Prevents accidental disconnect from being bumped or from vibration. Works with any IEC plug, no need to buy special cables or brackets.

    Easy Configuration

    Includes a central advanced LCD display with a menu system. Change settings incl. IP address, configure via USB stick copy/paste configuration file or configure En Masse via IPM software.

    Low profile chassis

    The ePDU doesn’t protrude into the rack and is low profile even at the breakers. 52mm wide x 53mm high and 58.7mm at breakers on most models. Hydraulic-Magnetic Circuit Breakers include accidental-tip protection by default.

    No Downtime on Upgrades

    ePDU G3 has Hot-Swap network components - update or change without changing the outlet state.

    Email product to a friend
    Print product details
    View Keywording: