Eaton Pulsar M 3000 3u Rackmount/Tower UPS

Manufacturer No.: 68402
This product is no longer available from Comms Express.
Overview
Details
On-line double conversion UPS with automatic bypass, 3000VA/2700W, modular (2N or N+1) with ModularEasy kit, versatile Tower/Rack3U short depth, multilingual LCD display, 8 IEC 10A outlets including 4 Powershare + 1 IEC 16A, hot swappable batteries, power management software, USB and Serial port, slot for optional management card
Maximum availability
- Configuration. Double conversion on-line UPS with automatic by-pass and power factor correction.
- Continuous power supply. Hot swappable batteries. The HotSwap MBP (Maintenance By-Pass) module allows the battery to be replaced without interrupting the power supply
- Powershare. The Pulsar output sockets are individually controlled to provide load-shedding to maximise the backup time. It also provides remote reboot and sequential start-up as standard.
- Long backup times. 1 to 4 EXB battery units can be added to the Pulsar M. The Pulsar 3000XL has a built-in high speed charger for additional long backup times.
Minimum total cost of ownership
- Easy operation. Multilingual display. Access to a wide range of measurements and set-up menus.
- Remote supervision. A wide range of options using the Solution-Pac supplied: SNMP and HTML, ( Network Management Card included with Netpack versions), ModBus/JBus and relay outputs.
Totally adaptable
- Format. Pulsar M is available in RT2U convertible rack/tower version (optimised for rack mounting) or RT3U (for tower or shallow rack).
- Connections. With FlexPDU and HotSwap MBP the Pulsar M can be connected by sockets or terminal blocks. They can be installed as required behind, on the side or on top of the unit.
- Compatible with high power factor loads. Pulsar M is rated for 0.9 total power factor
- Interfaces . USB + serial + remote start/stop + slot for optional communications card.
|
Technical specifications |
|
|
Technology |
ON-LINE double conversion with automatic bypass and Power factor correction system |
|
Power ratings |
3000 VA / 2700 W |
|
440 x 131 x 490 mm / 30 kg | |
|
Output connections |
8 IEC C13 (10A) + 1 IEC C19 (16A) outlet, including 2 groups of 2 IEC 10A Powershare outlets |
|
Input voltage range |
100/120/160 to 284V (for load level <20% / <33% / <66% / >=66% of rated output) |
|
Output voltage |
230V (adjustable to 200/208/220/240/250 V) |
|
Frequency |
Input range : 40-70 Hz, Output range : 50/60 Hz auto select or frequency converter mode |
|
Features |
Power factor correction system, Remote power off, Frequency converter mode (with 15% power derating), Cold start |
|
Battery features |
Automatic weekly test (periodicity adjustable via LCD display or software) |
|
User interface |
3 LEDS + Multilingual LCD : access to measures, alarm messages and customization |
| Warranty |
2 years – Optional 3 years warranty with Warranty+ (depending on country) |
|
Administration |
1 USB port + 1 serial RS232 & contacts port + 1 mini-terminal block for remote ON/OFF & Remote Power Off, 1 slot for NMC Minislot 2006 Edition or NMC ModBus/Jbus or MC Contacts/Serial |
|
Standards and certifications |
IEC/EN 62040-3; IEC/EN 62040-1 -1; IEC/EN 60950-1 (RD), IEC/EN 62040-2 C1 class, CE, TüV GS, CB report, TüV-US |





0800 488 0000
0800 488 0001