Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Login
loading Gif
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Comms Express Finance Options
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Spend £100.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Browse Categories
End of Life Product
£POA
£POA Inc VAT.

If you wish to enquire about this product please contact us on
0800 488 0000

Sorry, this item is no longer available from Comms Express.

Tripp Lite 3.2-3.8kW Single-Phase ATS/Metered PDU, 200-240V (8 C13 & 2 C19), 2 C20, 12ft Cord

1U Rack-Mount

by Tripp Lite
See more product details
Part No:FEPDUMH20HVAT
Manufacturer No:PDUMH20HVAT
Delivery: End of Life Product
More Related Items
Click to change options
Colour:
Apply
£1.40 Ex VAT
Qty:
Click to change options
Length:
Colour:
Apply
£0.78 Ex VAT
Qty:
Click to change options
Colour:
Apply
£222.67 Ex VAT
Qty:
Click to change options
Length:
Fibre Size:
Apply
£4.89 Ex VAT
Qty:
Email product to a friend
X
  • Scroll to top
    Tripp Lite 3.2-3.8kW Single-Phase ATS/Metered PDU, 200-240V (8 C13 & 2 C19), 2 C20, 12ft Cord
    1U Rack-Mount
    Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable.

    Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application.

    ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.

    Key Features

    • 200-240V 16/20A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 16A continuous)
    • Provides a redundant power option for critical networking equipment with a single input power cord
    • 2 digit display reports output power consumption in amps
    • 1U horizontal rackmount form factor; 14.8 in. / 37.6 cm depth
    • 10 outlets (8 C13, 2 C19)
    • Set of two C20 inlets support connection to separate PRIMARY and SECONDARY power sources
    • Two 12ft / 3.6m C19 to C20 power cables included
    • ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
    • ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
    • Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
    • On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
    • Super-fast switchover between primary and secondary power sources occurs in 2-5 milliseconds
    • Built-in card slot supports optional SNMPWEBCARD or WEBCARDLX for permanent upgrade to a switched & monitored PDU system
    • Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup
    • Front panel LEDs confirm power availability on both input lines
    • Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases

    This Package Includes

    • Metered PDU with ATS Support
    • User manual with warranty information

    Overview

    Tripp Lite Metered Automatic Transfer Switch / ATS PDU provides a redundant power option for network devices powered by a non-redundant power supply configuration. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications.

    Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.


    Features

    • 200-240V 16/20A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 16A continuous)
    • Provides a redundant power option for critical networking equipment with a single input power cord
    • 2 digit display reports output power consumption in amps
    • 1U horizontal rackmount form factor; 14.8 in. / 37.6 cm depth
    • 10 outlets (8 C13, 2 C19)
    • Set of Plug-lock output power cable retention sleeves prevent accidental disconnection of connected devices
    • Set of two C20 inlets support connection to separate PRIMARY and SECONDARY power sources
    • Two 12ft / 3.6m C19 to C20 power cables included
    • ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
    • ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
    • Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
    • On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
    • Super-fast switchover between primary and secondary power sources occurs in 2-5 milliseconds
    • Built-in card slot supports optional SNMPWEBCARD or WEBCARDLX for permanent upgrade to a switched & monitored PDU system
    • Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup
    • Front panel LEDs confirm power availability on both input lines
    • Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases

    Package Includes

    • Metered PDU with ATS Support
    • 2x IEC C19-to-C20 AC input cables
    • Plug-lock cable retention sleeves
    • Plug-lock cable retention sleeves
    • User manual with warranty information
    Email product to a friend
    Print product details
    View Keywording: