Easter Bank Holiday Weekend
Early Closing Thursday

We will be closing early on Thursday 28th March at 16:30

Last orders: 16:00 (next day: 15:30) | CLOSED - Good Friday & Easter Monday

Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Login
loading Gif
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Comms Express Finance Options
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Spend £100.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Browse Categories
End of Life Product
£POA
£POA Inc VAT.

If you wish to enquire about this product please contact us on
0800 488 0000

Sorry, this item is no longer available from Comms Express.

/assets/images/gallery/large/Multi-Sentry-front-full1.jpg

Riello MST 10-T4 10kVA Multi Sentry UPS with 28 minutes full load autonomy
scroll
to top

Riello MST 10-T4 10kVA Multi Sentry UPS with 28 minutes full load autonomy

440x850x1320

by Riello
See more product details
Part No:RIMST10-T4
Manufacturer No:MST 10-T4
Delivery: End of Life Product

/assets/images/gallery/large/Multi-Sentry-front-full1.jpg

Riello MST 10-T4 10kVA Multi Sentry UPS with 28 minutes full load autonomy
scroll
to top
Email product to a friend
X
  • Scroll to top
    Riello MST 10-T4 10kVA Multi Sentry UPS with 28 minutes full load autonomy
    440x850x1320
    Highlights:
    • Large power size selection 10, 12, 15, 20 kVA
    • Small footprint
    • Zero impact source
    • Flexibility of use
    • Advanced communications
    The Multi Sentry series is ideal for protecting data centres and telecommunications systems, IT networks and critical systems in general, where the risks connected with poor energy supply can compromise the continuity of activities and services. The Multi Sentry series is available in 10-12-15-20 kVA models with threephase/single-phase input and single-phase output, and 10-12-15-20 kVA models with three-phase input and output and on-line double conversion technology in accordance with VFI-SS-111 classification (as set out in standard IEC EN 62040-3). Multi Sentry is designed and built using state-of-the-art technology and components. It is controlled by a DSP (Digital Signal Processor) microprocessor, to provide maximum protection to the powered loads with no impact on downstream systems, and optimised energy savings.

    Zero impact source

    Multi Sentry solves installation problems in systems where the power supply has limited power available, where the UPS is supported by a generator or where there are compatibility problems with loads that generate harmonic currents; Multi Sentry has a zero impact on its power source, whether this is the mains power supply or a generator:
    • input current distortion < 3%
    • input power factor 0.99
    • power walk-in function that ensures progressive rectifier start up
    • start-up delay function, to restart the rectifiers when mains power is restored if there are several UPS in the system.
    In addition, Multi Sentry plays a filtering and power factor correction role in the power network upstream of the UPS, as it eliminates harmonic components and reactive power generated by the power utilities.

    Battery care system
     
    Proper battery care is critical to ensuring correct UPS operation in emergency conditions. The Riello UPS battery care system consists of a series of features and capabilities to optimise battery management and obtain the best performance and operating life possible. Battery recharging: Multi Sentry is suitable for use with hermetically sealed lead-acid (VRLA), AGM and GEL batteries and Open Vent and Nickel Cadmium batteries. Depending on the battery type, different charging methods are available:
    • One-level voltage recharge, typically used for widely available VRLA AGM batteries
    • Two-level voltage recharge according to IU specification
    • Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries.
    Recharge voltage compensation based on temperature in order to prevent excessive battery charges or overheating. Battery tests to diagnose in advance any reduction in performance or problems with the batteries. Deep discharge protection: during extended low-load discharges, the end-of-discharge voltage is increased - as recommended by battery manufacturers - to prevent damage or reduced battery performance. Ripple current: recharge ripple current (residual AC component) is one of the main causes of reduced reliability and battery life. Using a high frequency battery charger, Multi Sentry reduces this value to negligible levels, prolonging battery life and maintaining high performance over a long period of time. Wide voltage range: the rectifier is designed to operate within a wide input voltage range (up to - 40% at half load), reducing the need for battery discharge and thus helping to extend battery life.
    Maximum reliability and availability
    Distributed parallel configuration of up to 8 units per redundant (N+1) or power parallel system. The UPS continue to operate in parallel even if the connection cable is interrupted (Closed Loop).

    Operation flexibility
    The compact version of the Multi Sentry (MCM/MCT 10, 12, 15, 20 kVA) features embedded auxiliary outlets for intelligent utilities supply. The “energy share” outlet is driven by relays which are customizable depending on the installation or customer needs, making it more suitable for protecting different critical load. On the MSM/MST Multi Sentry version the same functionality is available as optionally.

    Advanced communications
    Multi Sentry is equipped with a back-lit graphic display (240x128 pixels) providing UPS information, measurements, operating states and alarms in different languages. It can also display wave forms and voltage/ current forms. A wide range of comunications options are available to ensure global and comprehensive UPS monitoring. Please refer to option table for details.
     
    USB Plug USB Plug Energy Share
    Service 1st Start Tower
    E-Medical Online 
    Industry Emergency
    Smart Grid Ready UPS Transport
    Supercaps UPS Superscaps UPS Datacentre
    Eco Level 6    

    Eco Energy: efficiency level

    Riello UPS 's social commitment aims to help the present as well as shape a bright future, combining the inevitable need for energy with environmental protection.

    Riello UPS uninterruptible power supplies power some of the most critical data centres and servers in use today. Within these environments, energy management is critical. Running costs must be minimised without compromising resilience, i.e. the ability to adapt to adverse external conditions whilst ensuring the complete availability of the services provided. Equipment must operate at the highest possible levels of efficiency to reduce the strain on critical power supplies and minimise the effect on the installation area.

    Riello UPS models have always been compliant with the highest levels of efficiency in terms of energy protection and are classified according to a scale with 6 levels, corresponding with the efficiency value of the UPS with respect to the European Code of Conduct; this is known as the Eco Energy Level.



    The Eco Energy Level system demonstrates how the most efficient UPS provide energy savings that allow the cost of their purchase to be recovered quickly compared to standard efficiency UPS , as well as how their use leads to significant reductions in carbon emissions into the atmosphere.

    Highlights:
    • Large power size selection 10, 12, 15, 20 kVA
    • Small footprint
    • Zero impact source
    • Flexibility of use
    • Advanced communications
    The Multi Sentry series is ideal for protecting data centres and telecommunications systems, IT networks and critical systems in general, where the risks connected with poor energy supply can compromise the continuity of activities and services. The Multi Sentry series is available in 10-12-15-20 kVA models with threephase/single-phase input and single-phase output, and 10-12-15-20 kVA models with three-phase input and output and on-line double conversion technology in accordance with VFI-SS-111 classification (as set out in standard IEC EN 62040-3). Multi Sentry is designed and built using state-of-the-art technology and components. It is controlled by a DSP (Digital Signal Processor) microprocessor, to provide maximum protection to the powered loads with no impact on downstream systems, and optimised energy savings.

    Zero impact source

    Multi Sentry solves installation problems in systems where the power supply has limited power available, where the UPS is supported by a generator or where there are compatibility problems with loads that generate harmonic currents; Multi Sentry has a zero impact on its power source, whether this is the mains power supply or a generator:
    • input current distortion < 3%
    • input power factor 0.99
    • power walk-in function that ensures progressive rectifier start up
    • start-up delay function, to restart the rectifiers when mains power is restored if there are several UPS in the system.
    In addition, Multi Sentry plays a filtering and power factor correction role in the power network upstream of the UPS, as it eliminates harmonic components and reactive power generated by the power utilities.

    Battery care system
     
    Proper battery care is critical to ensuring correct UPS operation in emergency conditions. The Riello UPS battery care system consists of a series of features and capabilities to optimise battery management and obtain the best performance and operating life possible. Battery recharging: Multi Sentry is suitable for use with hermetically sealed lead-acid (VRLA), AGM and GEL batteries and Open Vent and Nickel Cadmium batteries. Depending on the battery type, different charging methods are available:
    • One-level voltage recharge, typically used for widely available VRLA AGM batteries
    • Two-level voltage recharge according to IU specification
    • Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries.
    Recharge voltage compensation based on temperature in order to prevent excessive battery charges or overheating. Battery tests to diagnose in advance any reduction in performance or problems with the batteries. Deep discharge protection: during extended low-load discharges, the end-of-discharge voltage is increased - as recommended by battery manufacturers - to prevent damage or reduced battery performance. Ripple current: recharge ripple current (residual AC component) is one of the main causes of reduced reliability and battery life. Using a high frequency battery charger, Multi Sentry reduces this value to negligible levels, prolonging battery life and maintaining high performance over a long period of time. Wide voltage range: the rectifier is designed to operate within a wide input voltage range (up to - 40% at half load), reducing the need for battery discharge and thus helping to extend battery life.
    Maximum reliability and availability
    Distributed parallel configuration of up to 8 units per redundant (N+1) or power parallel system. The UPS continue to operate in parallel even if the connection cable is interrupted (Closed Loop).

    Operation flexibility
    The compact version of the Multi Sentry (MCM/MCT 10, 12, 15, 20 kVA) features embedded auxiliary outlets for intelligent utilities supply. The “energy share” outlet is driven by relays which are customizable depending on the installation or customer needs, making it more suitable for protecting different critical load. On the MSM/MST Multi Sentry version the same functionality is available as optionally.

    Advanced communications
    Multi Sentry is equipped with a back-lit graphic display (240x128 pixels) providing UPS information, measurements, operating states and alarms in different languages. It can also display wave forms and voltage/ current forms. A wide range of comunications options are available to ensure global and comprehensive UPS monitoring. Please refer to option table for details.
     
    USB Plug USB Plug Energy Share
    Service 1st Start Tower
    E-Medical Online 
    Industry Emergency
    Smart Grid Ready UPS Transport
    Supercaps UPS Superscaps UPS Datacentre
    Eco Level 6    

    Eco Energy: efficiency level

    Riello UPS 's social commitment aims to help the present as well as shape a bright future, combining the inevitable need for energy with environmental protection.

    Riello UPS uninterruptible power supplies power some of the most critical data centres and servers in use today. Within these environments, energy management is critical. Running costs must be minimised without compromising resilience, i.e. the ability to adapt to adverse external conditions whilst ensuring the complete availability of the services provided. Equipment must operate at the highest possible levels of efficiency to reduce the strain on critical power supplies and minimise the effect on the installation area.

    Riello UPS models have always been compliant with the highest levels of efficiency in terms of energy protection and are classified according to a scale with 6 levels, corresponding with the efficiency value of the UPS with respect to the European Code of Conduct; this is known as the Eco Energy Level.



    The Eco Energy Level system demonstrates how the most efficient UPS provide energy savings that allow the cost of their purchase to be recovered quickly compared to standard efficiency UPS , as well as how their use leads to significant reductions in carbon emissions into the atmosphere.