Hi there! Our website may store cookies on your computer in order to give you
the best experience, such as remembering the items in your cart so you
can continue shopping where you left off.
By continuing to use our site, you give consent for cookies to be used.
Sentinel Power is the ideal solution for powering sensitive, mission critical systems such as safety devices (electro-medical devices), ensuring maximum power reliability. The series includes 5-6 kVA single/singlephase and 6,5-8-10 kVA single/single-phase and three/single-phase models with on-line double conversion technology (VFI): the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilised in terms of voltage, form and frequency. Input and output filters provide significant further immunity from mains disturbances and lightning strikes. In terms of technology, performance (selectable Economy and Smart Active Modes) and diagnostics (LCD custom display, RS232 and USB interfaces with Powershield3 software included, ESD input, interface slot for optional boards), Sentinel Power is one of the best UPS available on the market.
High UPS reliability
Total microprocessor control.
Interruption-free static and manual bypass.
Specifications guaranteed up to 40 °C (the components are designed to work at high temperatures and thus are subject to less stress at normal temperatures).
Operating mode selection
The operating mode can be programmed via software or manually via the front display panel.
On line.
Economy Mode: to increase efficiency (up to to 98%), allows for the selection of Line Interactive technology (VI) to power low priority loads from the mains supply.
Smart Active: the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply.
Emergency: the UPS can be selected to function only when the mains power supply fails (emergency only mode).
Frequency converter operation (50 or 60 Hz).
High quality output voltage
Even with non-linear loads (IT loads with a crest factor of up to 3:1).
High short circuit current on bypass.
High overload capacity: 150% by inverter (even with mains failure).
Filtered, stabilised and reliable voltage (double conversion on-line technology - VFI compliant with EN62040-3), with filters for the suppression of atmospheric disturbances.
Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake
Simplified installation
UPS can be installed on a single-phase or three-phase distribution network
Output terminal board + 2 IEC sockets for powering local consumers (computers, modems, etc.)
Simplified positioning (built-in castors).
High battery reliability
Automatic and manual battery test
Reduced ripple component (detrimental to the batteries) using a low ripple current discharge (LCRD) system
Unlimited extendible runtime using matching Battery Boxes
The batteries do not cut in during mains failures of
Energy-share
Two 10 A configurable IEC output sockets allow for runtime optimisation by programming the switching off of low priority loads on mains failure; alternatively, emergency loads that are normally not powered when mains is present can be activated.
Low impact on the mains Sinusoidal uptake of input current on singlephase/single-phase series.
Other features
Advanced diagnostics: status, measurements and alarms available on custom LCD display
Low noise (20 kHz, value above audible range)
Auto restart (automatic when mains supply is restored, programmable via software or display panel)
Emergency function: the UPS can be selected to function only when the mains power supply fails (emergency lights)
Back-feed protection standard: to prevent energy from being fed back to the network
Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software for Windows operating systems 8, 7, Hyper-V, 2012, 2008, and previous versions, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems
RS232 serial port
Plug and play function
Slot for installation of communications boards
USB Plug
Energy Share
Service 1st Start
Tower
E-Medical
Online
Industry
Emergency
SoHo
Transport
Superscaps UPS
Datacentre
Eco Level 6
Eco Energy: efficiency level
Riello UPS 's social commitment aims to help the present as well as shape a bright future, combining the inevitable need for energy with environmental protection.
Riello UPS uninterruptible power supplies power some of the most critical data centres and servers in use today. Within these environments, energy management is critical. Running costs must be minimised without compromising resilience, i.e. the ability to adapt to adverse external conditions whilst ensuring the complete availability of the services provided. Equipment must operate at the highest possible levels of efficiency to reduce the strain on critical power supplies and minimise the effect on the installation area.
Riello UPS models have always been compliant with the highest levels of efficiency in terms of energy protection and are classified according to a scale with 6 levels, corresponding with the efficiency value of the UPS with respect to the European Code of Conduct; this is known as the Eco Energy Level.
The Eco Energy Level system demonstrates how the most efficient UPS provide energy savings that allow the cost of their purchase to be recovered quickly compared to standard efficiency UPS , as well as how their use leads to significant reductions in carbon emissions into the atmosphere.
Highlights
High UPS reliability
Operating mode selection
High quality output voltage
Simplified installation
High battery reliability
Low impact on the mains
Sentinel Power is the ideal solution for powering sensitive, mission critical systems such as safety devices (electro-medical devices), ensuring maximum power reliability. The series includes 5-6 kVA single/singlephase and 6,5-8-10 kVA single/single-phase and three/single-phase models with on-line double conversion technology (VFI): the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilised in terms of voltage, form and frequency. Input and output filters provide significant further immunity from mains disturbances and lightning strikes. In terms of technology, performance (selectable Economy and Smart Active Modes) and diagnostics (LCD custom display, RS232 and USB interfaces with Powershield3 software included, ESD input, interface slot for optional boards), Sentinel Power is one of the best UPS available on the market.
High UPS reliability
Total microprocessor control.
Interruption-free static and manual bypass.
Specifications guaranteed up to 40 °C (the components are designed to work at high temperatures and thus are subject to less stress at normal temperatures).
Operating mode selection
The operating mode can be programmed via software or manually via the front display panel.
On line.
Economy Mode: to increase efficiency (up to to 98%), allows for the selection of Line Interactive technology (VI) to power low priority loads from the mains supply.
Smart Active: the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply.
Emergency: the UPS can be selected to function only when the mains power supply fails (emergency only mode).
Frequency converter operation (50 or 60 Hz).
High quality output voltage
Even with non-linear loads (IT loads with a crest factor of up to 3:1).
High short circuit current on bypass.
High overload capacity: 150% by inverter (even with mains failure).
Filtered, stabilised and reliable voltage (double conversion on-line technology - VFI compliant with EN62040-3), with filters for the suppression of atmospheric disturbances.
Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake
Simplified installation
UPS can be installed on a single-phase or three-phase distribution network
Output terminal board + 2 IEC sockets for powering local consumers (computers, modems, etc.)
Simplified positioning (built-in castors).
High battery reliability
Automatic and manual battery test
Reduced ripple component (detrimental to the batteries) using a low ripple current discharge (LCRD) system
Unlimited extendible runtime using matching Battery Boxes
The batteries do not cut in during mains failures of
Energy-share
Two 10 A configurable IEC output sockets allow for runtime optimisation by programming the switching off of low priority loads on mains failure; alternatively, emergency loads that are normally not powered when mains is present can be activated.
Low impact on the mains Sinusoidal uptake of input current on singlephase/single-phase series.
Other features
Advanced diagnostics: status, measurements and alarms available on custom LCD display
Low noise (20 kHz, value above audible range)
Auto restart (automatic when mains supply is restored, programmable via software or display panel)
Emergency function: the UPS can be selected to function only when the mains power supply fails (emergency lights)
Back-feed protection standard: to prevent energy from being fed back to the network
UPS digital updating (flash upgradeable).
Advanced communications
Compatible with Riello UPS TeleNetGuard remote monitoring
Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software for Windows operating systems 8, 7, Hyper-V, 2012, 2008, and previous versions, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems
RS232 serial port
Plug and play function
Slot for installation of communications boards
USB Plug
Energy Share
Service 1st Start
Tower
E-Medical
Online
Industry
Emergency
SoHo
Transport
Superscaps UPS
Datacentre
Eco Level 6
Eco Energy: efficiency level
Riello UPS 's social commitment aims to help the present as well as shape a bright future, combining the inevitable need for energy with environmental protection.
Riello UPS uninterruptible power supplies power some of the most critical data centres and servers in use today. Within these environments, energy management is critical. Running costs must be minimised without compromising resilience, i.e. the ability to adapt to adverse external conditions whilst ensuring the complete availability of the services provided. Equipment must operate at the highest possible levels of efficiency to reduce the strain on critical power supplies and minimise the effect on the installation area.
Riello UPS models have always been compliant with the highest levels of efficiency in terms of energy protection and are classified according to a scale with 6 levels, corresponding with the efficiency value of the UPS with respect to the European Code of Conduct; this is known as the Eco Energy Level.
The Eco Energy Level system demonstrates how the most efficient UPS provide energy savings that allow the cost of their purchase to be recovered quickly compared to standard efficiency UPS , as well as how their use leads to significant reductions in carbon emissions into the atmosphere.
Email product to a friend Print product details
View Keywording:
Due to the size, weight and delicate nature of Data and Server Cabinets, specialist couriers are required so they arrive on site in pristine condition.
We do our utmost to bare the delivery costs meaning we can deliver your cabinet free of charge to most areas, unfortunately there are some areas of the UK we are charged a lot more to deliver to and whilst we absorb as much of this cost as we viably can in certain cases we have to pass on some of these costs. Below is a list of these areas and the additional costs of delivery per cabinet.