Easter Bank Holiday Weekend
Early Closing Thursday

We will be closing early on Thursday 28th March at 16:30

Last orders: 16:00 (next day: 15:30) | CLOSED - Good Friday & Easter Monday

Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Login
loading Gif
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Comms Express Finance Options
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Spend £100.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Browse Categories
End of Life Product
£POA
£POA Inc VAT.

If you wish to enquire about this product please contact us on
0800 488 0000

Sorry, this item is no longer available from Comms Express.

Geist Water Rope Sensor kit, 2 Wire

by Geist
See more product details
Length:
Part No:EMG-WR3
Manufacturer No:G-WROPE3M-SEN
Delivery: End of Life Product
More Related Items
Click to change options
Length:
Fibre Size:
Apply
£5.47 Ex VAT
Qty:
Click to change options
Colour:
Apply
£99.00 Ex VAT
Qty:
Email product to a friend
X
  • Scroll to top
    Geist Water Rope Sensor kit, 2 Wire

    Water lurks in walls, ceilings, floors and air conditioning evaporator trays - it can seriously damage your data room equipment. Geist water rope allows detection of moisture over a wide area. When attached to a Geist climate unit, and water is detected, alarms can be sent by email and/or SNMP trap. Geist water rope is available supplied to length required, to a maximum of 300 feet, using extensions.

    Connections:
    The sensing cable (orange wire) is attached to the floor using small nylon J-clips. It connects to the leader cable, which in turn is connected to the wall-mounted interface box. An LED on the box provides a visual indication of system status.

    Four signal wires connect to terminals on the interface box. One pair of wires detects water while the other pair can report damaged cable. Both sets of wires connect the interface box to the climate monitor.

    There are two options for connecting the signal wires to the Geist climate monitoring unit. One is to attach the wire to analogue input terminals. The second option is to use two CCAT interfaces (available as a Geist environmental monitoring accessory). Each CCAT converts the analogue signal into digital, allowing the use of digital sensor ports when analogue inputs aren’t available.

    Alarms:
    The Geist climate monitor continuously monitors the water rope to check whether water has been detected. If water is found the climate monitor follows the actions of the user-defined alarms. Options include: sending alerts through email or SNMP and, depending upon the specification of the climate unit, trigger an alarm buzzer or energise an output relay. Alarm thresholds are configured through the web interface provided by the Geist climate monitor.

    Water lurks in walls, ceilings, floors and air conditioning evaporator trays - it can seriously damage your data room equipment. Geist water rope allows detection of moisture over a wide area. When attached to a Geist climate unit, and water is detected, alarms can be sent by email and/or SNMP trap. Geist water rope is available supplied to length required, to a maximum of 300 feet, using extensions.

    Connections:
    The sensing cable (orange wire) is attached to the floor using small nylon J-clips. It connects to the leader cable, which in turn is connected to the wall-mounted interface box. An LED on the box provides a visual indication of system status.

    Four signal wires connect to terminals on the interface box. One pair of wires detects water while the other pair can report damaged cable. Both sets of wires connect the interface box to the climate monitor.

    There are two options for connecting the signal wires to the Geist climate monitoring unit. One is to attach the wire to analogue input terminals. The second option is to use two CCAT interfaces (available as a Geist environmental monitoring accessory). Each CCAT converts the analogue signal into digital, allowing the use of digital sensor ports when analogue inputs aren’t available.

    Alarms:
    The Geist climate monitor continuously monitors the water rope to check whether water has been detected. If water is found the climate monitor follows the actions of the user-defined alarms. Options include: sending alerts through email or SNMP and, depending upon the specification of the climate unit, trigger an alarm buzzer or energise an output relay. Alarm thresholds are configured through the web interface provided by the Geist climate monitor.