Leak Detection Kit
Water sensing cable kits feature detection cables that recognize the presence of water along the entire cable length. These kits are ideal for discovering moisture over a wide area such as the perimeter of a group of racks and cabinets. Get an email or SNMP alert when the cable comes in contact with water.
Leak Detection Extension Cables (sold separately):
Part Number:
8706 (10ft cable) 8708 (50ft cable) 8707 (25ft cable)
8709 (100ft cable)
Protect a room or a data cabinet with this water
Water lurks in walls, ceilings, floors and air conditioning evaporator trays – it can kill your gear fast. Detect moisture over a wide area. This leak detection cable can sense the presence of water or other conductive liquid over its entire length. Typically used to protect computer server rooms from water damage, the Leak Detection Kit attaches to a Geist Climate Monitor. When water is detected, the climate monitor sends alerts by e-mail or SNMP trap.
The sensing cable (orange wire) attaches to the floor using small nylon J-clips. The sensing cable connects to the leader cable which attaches to the wall mounted interface box. An LED on the box provides a visual indication of a system status.
Connecting to the Geist Climate Monitor
Four signal wires connect to terminals on the interface box. One pair of wires tells if water was detected, while the other tells if the cable is damaged (cable fault). These wires connect the interface box to the climate monitor. There are two ways to connect the signal wires to the Geist Climate Monitor. One option is to attach the wire to Analogue Input terminals. The other option is to use two Analogue to Digital Converters. Each Analogue to Digital Converter converts the analogue signal from a pair of wires into digital. This allows you to use digital sensor ports when Analogue Inputs aren’t available.
Alarms
The Geist Climate Monitor continuously monitors the Leak Detection Kit to see if water is detected. If so, the Geist Climate Monitor follows the actions indicated by user-defined alarms. Options include sending alerts through email or SNMP and depending on the Geist Climate Monitor, trigger an alarm buzzer or energize an output relay. Alarm thresholds are configured through the web interface provided by the Geist Climate Monitor.
Leak Detection Kit
Water sensing cable kits feature detection cables that recognize the presence of water along the entire cable length. These kits are ideal for discovering moisture over a wide area such as the perimeter of a group of racks and cabinets. Get an email or SNMP alert when the cable comes in contact with water.
Leak Detection Extension Cables (sold separately):
Part Number:
8706 (10ft cable) 8708 (50ft cable) 8707 (25ft cable)
8709 (100ft cable)
Protect a room or a data cabinet with this water
Water lurks in walls, ceilings, floors and air conditioning evaporator trays – it can kill your gear fast. Detect moisture over a wide area. This leak detection cable can sense the presence of water or other conductive liquid over its entire length. Typically used to protect computer server rooms from water damage, the Leak Detection Kit attaches to a Geist Climate Monitor. When water is detected, the climate monitor sends alerts by e-mail or SNMP trap.
The sensing cable (orange wire) attaches to the floor using small nylon J-clips. The sensing cable connects to the leader cable which attaches to the wall mounted interface box. An LED on the box provides a visual indication of a system status.
Connecting to the Geist Climate Monitor
Four signal wires connect to terminals on the interface box. One pair of wires tells if water was detected, while the other tells if the cable is damaged (cable fault). These wires connect the interface box to the climate monitor. There are two ways to connect the signal wires to the Geist Climate Monitor. One option is to attach the wire to Analogue Input terminals. The other option is to use two Analogue to Digital Converters. Each Analogue to Digital Converter converts the analogue signal from a pair of wires into digital. This allows you to use digital sensor ports when Analogue Inputs aren’t available.
Alarms
The Geist Climate Monitor continuously monitors the Leak Detection Kit to see if water is detected. If so, the Geist Climate Monitor follows the actions indicated by user-defined alarms. Options include sending alerts through email or SNMP and depending on the Geist Climate Monitor, trigger an alarm buzzer or energize an output relay. Alarm thresholds are configured through the web interface provided by the Geist Climate Monitor.