APC MGE Galaxy 300 10kVA 400V 3:3 with Long Backup Charger, Start-up 5x8
Effective three phase power protection against downtime and data loss for mission critical applications. UPS with long backup charger, supplied without batteries. To be used with external batteries.
Includes: Installation guide , Network Management Card , Start-Up Service , User Manual
Galaxy 300 Features & Benefits
Availability
Dual mains input - Allows standard installation of one or two independent power sources.
Automatic internal bypass - Built-in 100 percent rated bypass static switch prevents interruption by allowing load transfer to utility power during heavy overloads.
Parallel 1+1 for redundancy - Connected equipment can be powered with two UPS units in parallel to increase system redundancy.
Ruggedized design - With conformance-coated boards and included dust filter to better withstand harsh environments.
Integrated battery backup - Provides higher level of availability with up to 30 minutes of runtime.
A robust charger - Provides all-in-one solution for the most common runtime requirements.
Serviceability
Manual maintenance bypass - Easily accessible maintenance bypass allows complete isolation of each part of the system, facilitating maintenance operations without power interruption.
Front-access servicing - Push-open door and slide-out boards simplify installation and maintenance while minimizing space requirements.
World-class service organization - With worldwide support and multiple levels of after-sales services, our package or individual on-site service options are structured for you to choose what Schneider Electric can do for you.
Economy
Power factor corrected input - Prevents the need for oversizing cables, circuit breakers, and generator.
Temperature-compensated battery charging - Sensors monitor battery temperature and adjust charger voltage to prevent premature aging and extend battery lifetime.
Reduced footprint - Compact wide or narrow tower makes best use of available space.
Simplified Installation
Easy to install - Wheeled unit rolls into place and all wiring connections are easily identifiable for time-saving installation.
Start-up wizard - Step-by-step guidance and intuitive menu screens for easy set up and system navigation.
Manageability
Built-in management card for SNMP - Remote and local monitoring and management capabilities with simple Web/SNMP interface.
Effective three phase power protection against downtime and data loss for mission critical applications. UPS with long backup charger, supplied without batteries. To be used with external batteries.
Includes: Installation guide , Network Management Card , Start-Up Service , User Manual
Galaxy 300 Features & Benefits
Availability
Dual mains input - Allows standard installation of one or two independent power sources.
Automatic internal bypass - Built-in 100 percent rated bypass static switch prevents interruption by allowing load transfer to utility power during heavy overloads.
Parallel 1+1 for redundancy - Connected equipment can be powered with two UPS units in parallel to increase system redundancy.
Ruggedized design - With conformance-coated boards and included dust filter to better withstand harsh environments.
Integrated battery backup - Provides higher level of availability with up to 30 minutes of runtime.
A robust charger - Provides all-in-one solution for the most common runtime requirements.
Serviceability
Manual maintenance bypass - Easily accessible maintenance bypass allows complete isolation of each part of the system, facilitating maintenance operations without power interruption.
Front-access servicing - Push-open door and slide-out boards simplify installation and maintenance while minimizing space requirements.
World-class service organization - With worldwide support and multiple levels of after-sales services, our package or individual on-site service options are structured for you to choose what Schneider Electric can do for you.
Economy
Power factor corrected input - Prevents the need for oversizing cables, circuit breakers, and generator.
Temperature-compensated battery charging - Sensors monitor battery temperature and adjust charger voltage to prevent premature aging and extend battery lifetime.
Reduced footprint - Compact wide or narrow tower makes best use of available space.
Simplified Installation
Easy to install - Wheeled unit rolls into place and all wiring connections are easily identifiable for time-saving installation.
Start-up wizard - Step-by-step guidance and intuitive menu screens for easy set up and system navigation.
Manageability
Built-in management card for SNMP - Remote and local monitoring and management capabilities with simple Web/SNMP interface.
Due to the size, weight and delicate nature of Data and Server Cabinets, specialist couriers are required so they arrive on site in pristine condition.
We do our utmost to bare the delivery costs meaning we can deliver your cabinet free of charge to most areas, unfortunately there are some areas of the UK we are charged a lot more to deliver to and whilst we absorb as much of this cost as we viably can in certain cases we have to pass on some of these costs. Below is a list of these areas and the additional costs of delivery per cabinet.