Easter Bank Holiday Weekend
Early Closing Thursday

We will be closing early on Thursday 28th March at 16:30

Last orders: 16:00 (next day: 15:30) | CLOSED - Good Friday & Easter Monday

Call us FREE on 0800 488 000
X
X

Please Log In Below

Forgotten Password?
Retry
Login
loading Gif
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Remove all items from cart
Are you sure? Yes No
Learn more about how
to collect Data Points
for free gifts.
Comms Express Finance Options
Request A Quote
View Cart
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Spend £100.00 for
FREE DELIVERY.
Free delivery excludes heavy and bulky products
Browse Categories
In Stock: 1-2 Weeks
£1128.94
£1354.73 Inc VAT
Earn 564 Data Points when purchasing this product. More Info

/assets/images/gallery/large/1668686687AR3100X609-1.png

APC AR3100X609 NetShelter SX 42U 600mm  x 1070mm Enclosure
scroll
to top

APC AR3100X609 NetShelter SX 42U 600mm x 1070mm Enclosure

Without Sides Black

by APC
See more product details
Part No:APCAR3100X609
Manufacturer No:AR3100X609
Delivery: In Stock: 1-2 Weeks

/assets/images/gallery/large/1668686687AR3100X609-1.png

APC AR3100X609 NetShelter SX 42U 600mm  x 1070mm Enclosure
scroll
to top
More Related Items
Click to change options
Colour:
Apply
£222.67 Ex VAT
Qty:
Email product to a friend
X
  • Scroll to top
    APC AR3100X609 NetShelter SX 42U 600mm x 1070mm Enclosure
    Without Sides Black

    Standard enclosure for low to medium density server and networking applications.

    Compact width to optimize data center space. 42U height to easily roll through doorways.

    Includes: Baying hardware, Installation guide, Key(s), Mounting hardware, Pre-installed casters

    Adjustable mounting rails with captive hardware and rapid alignment

    The vertical mounting rails can be adjusted in 1/4 in (6.4 mm) increments covering virtually any mounting requirement for IT equipment. Easy alignment feature integrated into the enclosure mounting rail and side brace for quick alignment verification without the use of tools to verify alignment. U positions are numbered front and back for rapid installation of equipment.

    Cable access openings with pre-installed brushes

    Large cable access slots in the roof provide access for overhead cable egress. The bottom design allows for unobstructed cable access through a raised floor. Roof includes openings with brush strips pre-installed in locations biased towards the front of the enclosure to allow for data cable passthrough and provisions for air containment.

    Designed for enhanced structural stability

    A proven frame design, heavy-gauge mounting rails, and heavy-duty casters provide for 3000 lb (1364 kg) static (levelling feet) and 2250 lb (1023 kg) dynamic (castor) load ratings. Enclosures have been tested and approved to be combined with proper bolt-down accessories to meet various seismic requirements. Check apc.com for product documentation for specific requirements.

    Easily removable cable access roof

    Roof can be removed with simple pull-pin hinges for access during equipment installation or even with cabling already in place and routed through the cable openings. Once removed, the roof is reversible to reposition the larger cable openings for power distribution plugs and connectors.

    Enclosure adjustment tools and hardware provided

    All enclosures are provided standard with a hardware bag that includes hardware for mounting IT equipment and tools for simple enclosure adjustment.

    Enclosure assemble-to-order (ATO) options capable

    The Enclosure ATO (Assemble-to-Order) options provide a level of customization for enclosure customers beyond the standard enclosure models. This customization is limited to the assembly of the enclosure itself and does not include additional enclosure-mounted components. For example, the enclosure can be assembled without sides, doors, or without sides and doors. Check apc.com for enclosure size options and availability.

    Equipment mounting rails integrate with patch cabling systems

    Equipment mounting rails include zero U mounting holes beside the EIA 19" mounting space that allows the installation of Data Distribution Cable (DDC) patch systems without taking up any critical equipment U-space. AV and Networking enclosure designs do not include hole locations for integration of DDC cabling. Other 1U, 2U, and rear enclosure zero U options are available for use with these enclosures.

    Eyebolt support integrated into enclosure frame

    Integrated eyebolt holes at the top of the enclosure frame allow the enclosure to be lifted for movement and enclosure placement using eyebolt lifting mechanisms. Refer to enclosure user documentation for detailed specifications on eyebolt requirements and enclosure weight limits.

    Integrated electrical grounding

    The roof, side panels, and front and rear doors are grounded to the frame of the enclosure. Eight additional electrical grounding inserts are located on the frame for external grounding.

    Integrated joining hardware with multiple width enclosure alignment

    Enclosures include pre-installed joining hardware to join enclosures in a row and provide additional stability to the enclosure. The pre-installed joining hardware includes holes for joining to an adjacent enclosure at 600mm centers or 24in centers depending upon the floor layout.

    Integrated with InfraStruxure products

    Schneider Electric cooling, power distribution, and cable management products work seamlessly with IT enclosures to provide a complete infrastructure support system.

    Low-profile castors and adjustable leveling feet from underneath or above

    Enclosures are shipped standard with both leveling feet and castors. Leveling feet can be quickly adjusted through the use of a screwdriver or drill, eliminating the need to reach underneath with a wrench.

    Optimized for high capacity cable management systems

    NetShelter SX enclosures are optimized for use with high capacity cable management systems that attach to equipment mounting rails inside enclosures aligning with equipment mounting u-spaces and provide channels for routing and managing cabling.

    Perforated front door with curved profile

    Perforated front and rear doors provide ample ventilation for servers and networking equipment. Front door perforated area is optimized with a curved profile to provide greater surface area and allowance of more perforation coverage and higher perforation rating.

    Pre-installed full-enclosure height rear accessory channels

    Integrated and adjustable rear accessory channel provides zero U mounting locations for toolless accessories. Each channel has two mounting bays to support a combination of up to four accessories such as PDUs and vertical cable organizers. 1070mm (42in), 825mm (32 in), and deep enclosures and networking enclosures include two channels. 1200mm (48in) deep enclosures include four channels. Channels are pre-installed at the factory in the rear of the enclosure but can be moved to other locations of the enclosure along the side brace to resituate cable management where it is needed most.

    Quick release doors

    Front door can be moved to the opposite side or interchanged with rear doors. Doors are easily removed with simple lift-off design.

    Schneider Electric Rack Systems Compatible

    Compatible with a variety of Schneider Electric rack accessory products to provide the ability to create a complete rack system. Configure rack solutions using industry-leading Schneider Electric Design Portal - Small IT Solution Designer configurator complete with verification of product compatibility and useful 3rd party equipment catalog to aid in visualizing your ideal rack solution.

    Simple Selection

    No need to spend hours choosing from and compiling dozens of part numbers to create a single enclosure. Schneider Electric has made it easy by handling the details and providing complete enclosures with single part numbers.

    Special packaging options for shipping rack with equipment mounted

    Enclosures with shock packaging are standard enclosures with provisions in the packaging design and enclosure assembly for shipping the enclosures with equipment mounted inside. Check apc.com for enclosure size options and availability.

    Split rear doors

    Split rear doors improve access and serviceability to the rear of rack-mounted equipment. The split rear doors help to maximize floor space. Only 11 inches (279 mm) of clearance is required behind the enclosures to allow for door swing.

    Vendor-neutral EIA-310 19in Rack Mounting Compatibility Guaranteed

    Vendor-neutral mounting for guaranteed compatibility with all EIA-310 compliant 19" equipment. The "Fits Like a Glove" money-back guarantee provides peace of mind that all of your EIA-310-E compliant rack-mount equipment will physically fit in a NetShelter.

    Product Diagram:

    1. Adjustable vertical 0 U accessory channel
    2. Removable rear split doors
    3. Removable and reversible front door
    4. Cabinet frame
    5. Adjustable leveling feet
    1. Hardware bag
    2. Casters
    3. Removable and reversible front door
    4. Key for doors and side panels
    5. Vertical mounting flanges
    6. Roof

    Standard enclosure for low to medium density server and networking applications.

    Compact width to optimize data center space. 42U height to easily roll through doorways.

    Includes: Baying hardware, Installation guide, Key(s), Mounting hardware, Pre-installed casters

    Adjustable mounting rails with captive hardware and rapid alignment

    The vertical mounting rails can be adjusted in 1/4 in (6.4 mm) increments covering virtually any mounting requirement for IT equipment. Easy alignment feature integrated into the enclosure mounting rail and side brace for quick alignment verification without the use of tools to verify alignment. U positions are numbered front and back for rapid installation of equipment.

    Cable access openings with pre-installed brushes

    Large cable access slots in the roof provide access for overhead cable egress. The bottom design allows for unobstructed cable access through a raised floor. Roof includes openings with brush strips pre-installed in locations biased towards the front of the enclosure to allow for data cable passthrough and provisions for air containment.

    Designed for enhanced structural stability

    A proven frame design, heavy-gauge mounting rails, and heavy-duty casters provide for 3000 lb (1364 kg) static (levelling feet) and 2250 lb (1023 kg) dynamic (castor) load ratings. Enclosures have been tested and approved to be combined with proper bolt-down accessories to meet various seismic requirements. Check apc.com for product documentation for specific requirements.

    Easily removable cable access roof

    Roof can be removed with simple pull-pin hinges for access during equipment installation or even with cabling already in place and routed through the cable openings. Once removed, the roof is reversible to reposition the larger cable openings for power distribution plugs and connectors.

    Enclosure adjustment tools and hardware provided

    All enclosures are provided standard with a hardware bag that includes hardware for mounting IT equipment and tools for simple enclosure adjustment.

    Enclosure assemble-to-order (ATO) options capable

    The Enclosure ATO (Assemble-to-Order) options provide a level of customization for enclosure customers beyond the standard enclosure models. This customization is limited to the assembly of the enclosure itself and does not include additional enclosure-mounted components. For example, the enclosure can be assembled without sides, doors, or without sides and doors. Check apc.com for enclosure size options and availability.

    Equipment mounting rails integrate with patch cabling systems

    Equipment mounting rails include zero U mounting holes beside the EIA 19" mounting space that allows the installation of Data Distribution Cable (DDC) patch systems without taking up any critical equipment U-space. AV and Networking enclosure designs do not include hole locations for integration of DDC cabling. Other 1U, 2U, and rear enclosure zero U options are available for use with these enclosures.

    Eyebolt support integrated into enclosure frame

    Integrated eyebolt holes at the top of the enclosure frame allow the enclosure to be lifted for movement and enclosure placement using eyebolt lifting mechanisms. Refer to enclosure user documentation for detailed specifications on eyebolt requirements and enclosure weight limits.

    Integrated electrical grounding

    The roof, side panels, and front and rear doors are grounded to the frame of the enclosure. Eight additional electrical grounding inserts are located on the frame for external grounding.

    Integrated joining hardware with multiple width enclosure alignment

    Enclosures include pre-installed joining hardware to join enclosures in a row and provide additional stability to the enclosure. The pre-installed joining hardware includes holes for joining to an adjacent enclosure at 600mm centers or 24in centers depending upon the floor layout.

    Integrated with InfraStruxure products

    Schneider Electric cooling, power distribution, and cable management products work seamlessly with IT enclosures to provide a complete infrastructure support system.

    Low-profile castors and adjustable leveling feet from underneath or above

    Enclosures are shipped standard with both leveling feet and castors. Leveling feet can be quickly adjusted through the use of a screwdriver or drill, eliminating the need to reach underneath with a wrench.

    Optimized for high capacity cable management systems

    NetShelter SX enclosures are optimized for use with high capacity cable management systems that attach to equipment mounting rails inside enclosures aligning with equipment mounting u-spaces and provide channels for routing and managing cabling.

    Perforated front door with curved profile

    Perforated front and rear doors provide ample ventilation for servers and networking equipment. Front door perforated area is optimized with a curved profile to provide greater surface area and allowance of more perforation coverage and higher perforation rating.

    Pre-installed full-enclosure height rear accessory channels

    Integrated and adjustable rear accessory channel provides zero U mounting locations for toolless accessories. Each channel has two mounting bays to support a combination of up to four accessories such as PDUs and vertical cable organizers. 1070mm (42in), 825mm (32 in), and deep enclosures and networking enclosures include two channels. 1200mm (48in) deep enclosures include four channels. Channels are pre-installed at the factory in the rear of the enclosure but can be moved to other locations of the enclosure along the side brace to resituate cable management where it is needed most.

    Quick release doors

    Front door can be moved to the opposite side or interchanged with rear doors. Doors are easily removed with simple lift-off design.

    Schneider Electric Rack Systems Compatible

    Compatible with a variety of Schneider Electric rack accessory products to provide the ability to create a complete rack system. Configure rack solutions using industry-leading Schneider Electric Design Portal - Small IT Solution Designer configurator complete with verification of product compatibility and useful 3rd party equipment catalog to aid in visualizing your ideal rack solution.

    Simple Selection

    No need to spend hours choosing from and compiling dozens of part numbers to create a single enclosure. Schneider Electric has made it easy by handling the details and providing complete enclosures with single part numbers.

    Special packaging options for shipping rack with equipment mounted

    Enclosures with shock packaging are standard enclosures with provisions in the packaging design and enclosure assembly for shipping the enclosures with equipment mounted inside. Check apc.com for enclosure size options and availability.

    Split rear doors

    Split rear doors improve access and serviceability to the rear of rack-mounted equipment. The split rear doors help to maximize floor space. Only 11 inches (279 mm) of clearance is required behind the enclosures to allow for door swing.

    Vendor-neutral EIA-310 19in Rack Mounting Compatibility Guaranteed

    Vendor-neutral mounting for guaranteed compatibility with all EIA-310 compliant 19" equipment. The "Fits Like a Glove" money-back guarantee provides peace of mind that all of your EIA-310-E compliant rack-mount equipment will physically fit in a NetShelter.

    Product Diagram:

    1. Adjustable vertical 0 U accessory channel
    2. Removable rear split doors
    3. Removable and reversible front door
    4. Cabinet frame
    5. Adjustable leveling feet
    1. Hardware bag
    2. Casters
    3. Removable and reversible front door
    4. Key for doors and side panels
    5. Vertical mounting flanges
    6. Roof
    Email product to a friend
    Print product details
    View Keywording: