Harmonic mitigation and correction of Displacement Power Factor (DPF) for installations up to 1000 kVA, with or without distributed neutral circuit.
Reduction in rms current value, saving on electrical distribution equipment sizing
Reduces losses in distribution equipment, providing longer life and more effective utilization of capacity
Reduces utility demand and costs
Main features
Global compensation or individual harmonic compensation, selectable from H2 to H50
Correction of the displacement power factor, Cos ø also adjustable
Configurable for different types of load; computer loads, motors, etc.
IGBT technology, control by DSP
3 LEDs to indicate operating condition
Digital, 7-language display unit
Configuration and parameter assignment menu
Remote control
Redundant parallel connections
Wide range of current transformers
Improved electricity availability and business performance
Increased reliability and service life
Reduced risk of outages
Increased productivity by eliminating downtime due to poor load characteristics
Increased quality due to better process performance
Extended equipment life
Increased generator performance and life
Ultra-simple integration
AccuSine is extremely compact and can be mounted on a wall or installed in a switchgear cubicle
AccuSine can be connected in parallel, allowing units to be added as power demands increase, without disconnecting the supply
AccuSine adapts automatically to any single- phase or three-phase load and is compatible with any type of neutral system
Complies with current technical standards
AccuSine conforms to the set of three technical standards currently in force
Harmonics: IEC 61000-3-2 and IEC 61000-3-4
Power quality: EN 50160 and IEEE 519
Compatibility between electrical systems and products: IEC 61000-2-2 and IEC 61000-2-4
How does an active conditioner work?
The conditioner analyses the load harmonics and compensates according to the selected configuration
Neutralization of harmonics with choice of filter setting according to the application
Plus correction of Cos ø, either lagging or leading
Energy savings
AccuSine also corrects the Cos ø either lagging or leading, up to 1.0
Less current and a Cos ø close to unity signify a lower factor in terms of apparent and reactive power
A right-sized installation
Fewer harmonics and greater Cos ø signify less current, with the following benefits
Smaller cable cross-sections and a reduction in the size of switchgear
Less overloads on transformers and capacitors
Secured operation of generator sets
AccuSine SWP
Active harmonic conditioner
Harmonic mitigation and correction of Displacement Power Factor (DPF) for installations up to 1000 kVA, with or without distributed neutral circuit.
Reduction in rms current value, saving on electrical distribution equipment sizing
Reduces losses in distribution equipment, providing longer life and more effective utilization of capacity
Reduces utility demand and costs
Main features
Global compensation or individual harmonic compensation, selectable from H2 to H50
Correction of the displacement power factor, Cos ø also adjustable
Configurable for different types of load; computer loads, motors, etc.
IGBT technology, control by DSP
3 LEDs to indicate operating condition
Digital, 7-language display unit
Configuration and parameter assignment menu
Remote control
Redundant parallel connections
Wide range of current transformers
Improved electricity availability and business performance
Increased reliability and service life
Reduced risk of outages
Increased productivity by eliminating downtime due to poor load characteristics
Increased quality due to better process performance
Extended equipment life
Increased generator performance and life
Ultra-simple integration
AccuSine is extremely compact and can be mounted on a wall or installed in a switchgear cubicle
AccuSine can be connected in parallel, allowing units to be added as power demands increase, without disconnecting the supply
AccuSine adapts automatically to any single- phase or three-phase load and is compatible with any type of neutral system
Complies with current technical standards
AccuSine conforms to the set of three technical standards currently in force
Harmonics: IEC 61000-3-2 and IEC 61000-3-4
Power quality: EN 50160 and IEEE 519
Compatibility between electrical systems and products: IEC 61000-2-2 and IEC 61000-2-4
How does an active conditioner work?
The conditioner analyses the load harmonics and compensates according to the selected configuration
Neutralization of harmonics with choice of filter setting according to the application
Plus correction of Cos ø, either lagging or leading
Energy savings
AccuSine also corrects the Cos ø either lagging or leading, up to 1.0
Less current and a Cos ø close to unity signify a lower factor in terms of apparent and reactive power
A right-sized installation
Fewer harmonics and greater Cos ø signify less current, with the following benefits
Smaller cable cross-sections and a reduction in the size of switchgear
Less overloads on transformers and capacitors
Secured operation of generator sets
Email product to a friend Print product details
View Keywording:
Due to the size, weight and delicate nature of Data and Server Cabinets, specialist couriers are required so they arrive on site in pristine condition.
We do our utmost to bare the delivery costs meaning we can deliver your cabinet free of charge to most areas, unfortunately there are some areas of the UK we are charged a lot more to deliver to and whilst we absorb as much of this cost as we viably can in certain cases we have to pass on some of these costs. Below is a list of these areas and the additional costs of delivery per cabinet.