Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Learn more about how
to collect Data Points
for free gifts.
Remove all items from cart
Are you sure? Yes No
Request A Quote
View Cart
Apply for a Credit Account
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Browse Categories
Express UPS Finder
Select requirements to view suitable UPS' instantly from our entire range.
Reset
SmartOnline 220-240V 3kVA 2.1kW On-Line Double-Conversion UPS

Tripp Lite's SmartOnline SUINT3000XL on-line, double-conversion UPS protects critical server, networking and telecommunications equipment from blackouts, voltage fluctuations and transient surges.

Space-saving upright tower format. Large capacity 3000VA/2100W UPS continuously converts incoming AC to DC, then back to perfect sine wave AC output at selectable 220/230/240V AC (+/-2%). Removes harmonic distortion, fast electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other UPS types. True sine wave output and zero transfer time offers guaranteed compatibility with all equipment types.

Includes 8 C13 outlets. Includes slot for internal SNMP/Web card, plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data.

Key Features True on-line, double conversion UPS provides pure sine wave AC output at all times
Maintains continuous operation with zero transfer time through blackouts, voltage fluctuations and surges
Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
Corrects brownouts and overvoltages from 175-280V at full load. Input voltage range extends to 80-280V at 50% load or less
3000VA/2100W power capacity with 8 C13 outlets
IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
Standard internal battery set provides 14 min. runtime at half load and 5 min. runtime at full load
Expandable runtime with multiple external battery packs (part# BP72V18 MULTI-PACK COMPATIBLE)
DB9 serial port for network interface; SNMP compatible
Slot for optional SNMP/Web card (part# SNMPWEBCARD)
PowerAlert unattended shutdown software and network cable included
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Diagnostic LEDs
Optional PDUBHV20 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
3 C13-to-C14 jumper cables included
This Package Includes SUINT3000XL UPS System
Serial cable
3 C13-to-C14 jumper cables
Owner's manual with warranty information

View More
In Stock: 3 - 5 Days
Was: £872.17
£852.79
£1023.35 Inc Vat.
Sorry, this item is no longer available from Comms Express.
2U SmartOnline 200-240V 3kVA 2.5kW On-Line Double-Conversion UPS

3000VA / 3kVA / 2500 watt on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 66cm (26 inches).

Expandable battery runtime with optional BP72V15-2U (limit 1) and BP72V28RT3U (multi-pack compatible) external battery packs. Full time sine wave 200/208/220/230/240V output with +/-2% voltage regulation. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 120V and overvoltages to 288V.

Up to 97% efficiency in optional economy mode saves BTU heat output and energy costs. C20 inlet accepts a wide variety of optional cordsets. C19 and C13 output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation.

Network management interfaces include USB port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces. Includes PowerAlert monitoring software and complete cabling.

Emergency Power Off (EPO) interface. Integrated two bank PDU switching supports automated load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring and battery charge status LEDs. Mains power and voltage regulation LEDs. Audible Alarm.

Self-test. Fault-tolerant auto-bypass mode. LED display panel easily rotates for better viewing in rackmount or tower configurations. Includes 4 post rackmount installation accessories. 2-9USTAND tower kit and 2POSTRMKITWM two post rackmount and wall-mount hardware accessories available. Field replaceable, hot swappable internal batteries and external battery packs.
Key Features SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications
Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation
Economy mode is schedulable via PowerAlert UPS management software for daily or weekly hours of operation to enable precision output during peak operating hours and high efficiency, low BTU emission operation during off-peak times
Maintains continuous operation through blackouts, voltage fluctuations
On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 200/208/220/230/240V(user selectable) with zero transfer time
Supports operation at 50/60Hz(auto-sensing) with the ability for full-time frequency conversion from 50 to 60Hz or 60 to 50Hz(frequency conversion de-rates UPS capacity by 20%)
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
Corrects line voltage conditions as low as 120V and as high as 288V to within 2% of selected nominal voltage
Standard internal battery set offers 15 minutes runtime at half load(1250W) and 6 minutes at full load(2500W)
Expandable battery runtime with optional BP72V15-2U(limit 1), BP72V28RT-3U(multi-pack compatible) and BP72V18-2US(multi-pack compatible) external battery packs
Intelligent battery management system extends battery life
Compact rackmount form factor installs using only 2 rack spaces(2U) with a depth of only 66cm / 26 inches
Ships with all mounting accessories for 4 post rackmount installation
Optional 2POSTRMKITWM enables 2 post rackmount installation
Optional 2-9USTAND accessory enables upright tower placement
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and slot for network management card options, such as Tripp Lite's SNMPWEBCARD network interface
HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints
Built-in Emergency Power Off(EPO) interface with cable
C20 inlet accepts a wide variety of user supplied input cordsets
C19 & C13 output receptacles
Includes 2 C13 to C14 and 1 C19 to C20 power cables
Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks(each bank has 4 C13 outlets)
Front panel LEDs offer current monitoring and battery charge level information
Network grade AC surge suppression
Optional PDUBHV20 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
Field replaceable, hot swappable internal batteries and external battery packs
This Package Includes SUINT3000RTXL2U UPS System
4 post rackmount installation brackets
C19 to C20 power cable
USB, Serial and EPO cabling
Owner's manual with warranty information

View More
In Stock: 3 - 5 Days
Was: £1,214.09
£1146.64
£1375.97 Inc Vat.
Qty:
Other Ranges Available
Tripp Lite Line Interactive 1500VA - 3000VA
Tripp Lite Line Interactive 1500VA - 3000VA
View Range
Join Our Mailing List
Join Now
View this week's eShot
Social Links
  • Apply for Credit