X
Forgotten Password?
Retry
Login
Sorry! You can't edit your cart on this page.
Sorry! This item could not be added to your cart as it is no longer available from Comms Express.
Please check the quantity you are adding and try again.
The following item has been added to your cart.
Product Code:
Options:
Qty:
Unit Price:£
View Cart
Checkout
Your cart is empty.
Subtotal:
£0
Learn more about how
to collect Data Points
for free gifts.
Remove all items from cart
Are you sure? Yes No
Request A Quote
View Cart
Apply for a Credit Account
Checkout
Cookie Policy×

Hi there! Our website may store cookies on your computer in order to give you the best experience, such as remembering the items in your cart so you can continue shopping where you left off.

By continuing to use our site, you give consent for cookies to be used.

Browse Categories
Express UPS Finder
Select requirements to view suitable UPS' instantly from our entire range.
Reset
Standard Model

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 4000 TWIN PRO2 4kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 4 kVA. The SLC 4000 TWIN PRO2 4kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=1
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 4000 TWIN PRO2 UPS Power (VA / W) 4000 / 4000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110 ÷ 276 V (2) Total harmonic distortion (THDi) <4% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 1 Total harmonic distortion (THDv) ≤1% linear load;
≤4% non-linear load Performance (normal mode) 93% ÷ 94% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs No Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 7-9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes (4) Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre Less than 60dB Dimensions (D x W x H mm) 592 x 250 x 576 Weight 81Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%
(4) Power reduction to 60%

View More
In Stock: Next Day
£868.94
£1042.73 Inc Vat.
Qty:
No Internal Batteries

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 4000 TWIN PRO2 4kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 4 kVA. The SLC 4000 TWIN PRO2 4kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=1
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 4000 TWIN PRO2 UPS Power (VA / W) 4000 / 4000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110 ÷ 276 V (2) Total harmonic distortion (THDi) <4% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 1 Total harmonic distortion (THDv) ≤1% linear load;
≤4% non-linear load Performance (normal mode) 93% ÷ 94% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs No Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 7-9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes (4) Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 592 x 250 x 576 Weight 81Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%
(4) Power reduction to 60%

View More
In Stock: Next Day
£706.02
£847.22 Inc Vat.
Qty:
Standard Model

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 5000 TWIN PRO2 5kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 5 kVA. The SLC 5000 TWIN PRO2 5kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=1
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 5000 TWIN PRO2 UPS Power (VA / W) 5000 / 5000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110 ÷ 276 V (2) Total harmonic distortion (THDi) <4% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 1 Total harmonic distortion (THDv) ≤1% linear load;
≤4% non-linear load Performance (normal mode) 93% ÷ 94% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs No Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 7-9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes (4) Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 592 x 250 x 576 Weight 82Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%
(4) Power reduction to 60%

View More
In Stock: Next Day
£964.28
£1157.14 Inc Vat.
Qty:
No Internal Batteries

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 5000 TWIN PRO2 5kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 5 kVA. The SLC 5000 TWIN PRO2 5kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=1
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 5000 TWIN PRO2 UPS Power (VA / W) 5000 / 5000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110 ÷ 276 V (2) Total harmonic distortion (THDi) <4% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 1 Total harmonic distortion (THDv) ≤1% linear load;
≤4% non-linear load Performance (normal mode) 93% ÷ 94% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs No Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 7-9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes (4) Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 592 x 250 x 576 Weight 82Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%
(4) Power reduction to 60%

View More
In Stock: Next Day
£748.26
£897.91 Inc Vat.
Qty:
Standard Model

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 6000 TWIN PRO2 6kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 6 kVA. The SLC 6000 TWIN PRO2 6kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=1
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 6000 TWIN PRO2 UPS Power (VA / W) 6000 / 6000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110 ÷ 276 V (2) Total harmonic distortion (THDi) <4% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 1 Total harmonic distortion (THDv) ≤1% linear load;
≤4% non-linear load Performance (normal mode) 93% ÷ 94% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs No Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 7-9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes (4) Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 592 x 250 x 576 Weight 83Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%
(4) Power reduction to 60%

View More
In Stock: Next Day
£1025.83
£1231.00 Inc Vat.
Qty:
No Internal Batteries

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 6000 TWIN PRO2 6kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 6 kVA. The SLC 6000 TWIN PRO2 6kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=1
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 6000 TWIN PRO2 UPS Power (VA / W) 6000 / 6000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110 ÷ 276 V (2) Total harmonic distortion (THDi) <4% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 1 Total harmonic distortion (THDv) ≤1% linear load;
≤4% non-linear load Performance (normal mode) 93% ÷ 94% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs No Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 7-9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes (4) Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 592 x 250 x 576 Weight 83Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%
(4) Power reduction to 60%

View More
In Stock: Next Day
£796.53
£955.84 Inc Vat.
Qty:
Standard Model

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 8000 TWIN PRO2 8kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 8 kVA. The SLC 8000 TWIN PRO2 8kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=1
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 8000 TWIN PRO2 UPS Power (VA / W) 8000 / 8000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110 ÷ 276 V (2) Total harmonic distortion (THDi) <4% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 1 Total harmonic distortion (THDv) ≤1% linear load;
≤4% non-linear load Performance (normal mode) 93% ÷ 94% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs No Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 7-9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes (4) Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 592 x 250 x 576 Weight 84Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%
(4) Power reduction to 60%

View More
In Stock: Next Day
£1098.24
£1317.89 Inc Vat.
Qty:
No Internal Batteries

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 8000 TWIN PRO2 8kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 8 kVA. The SLC 8000 TWIN PRO2 8kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=1
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 8000 TWIN PRO2 UPS Power (VA / W) 8000 / 8000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110 ÷ 276 V (2) Total harmonic distortion (THDi) <4% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 1 Total harmonic distortion (THDv) ≤1% linear load;
≤4% non-linear load Performance (normal mode) 93% ÷ 94% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs No Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 7-9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes (4) Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 592 x 250 x 576 Weight 84Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%
(4) Power reduction to 60%

View More
In Stock: Next Day
£995.67
£1194.80 Inc Vat.
Qty:
Standard Model

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 10000 TWIN PRO2 10kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 10 kVA. The SLC 10000 TWIN PRO2 10kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=1
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 10000 TWIN PRO2 UPS Power (VA / W) 10000 / 10000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110 ÷ 276 V (2) Total harmonic distortion (THDi) <4% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 1 Total harmonic distortion (THDv) ≤1% linear load;
≤4% non-linear load Performance (normal mode) 93% ÷ 94% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs No Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 7-9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes (4) Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 592 x 250 x 576 Weight 85Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%
(4) Power reduction to 60%

View More
In Stock: Next Day
£1327.54
£1593.05 Inc Vat.
Qty:
No Internal Batteries

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 10000 TWIN PRO2 10kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 10 kVA. The SLC 10000 TWIN PRO2 10kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=1
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 10000 TWIN PRO2 UPS Power (VA / W) 10000 / 10000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110 ÷ 276 V (2) Total harmonic distortion (THDi) <4% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 1 Total harmonic distortion (THDv) ≤1% linear load;
≤4% non-linear load Performance (normal mode) 93% ÷ 94% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs No Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 7-9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes (4) Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 592 x 250 x 576 Weight 85Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%
(4) Power reduction to 60%

View More
In Stock: Next Day
£1025.83
£1231.00 Inc Vat.
Qty:
Standard Model

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 15000 TWIN PRO2 15kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 15 kVA. The SLC 15000 TWIN PRO2 15kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=0.9
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 15000 TWIN PRO2 UPS Power (VA / W) 15000 / 13500 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110-276 V (2) Total harmonic distortion (THDi) <5% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 0.9 Total harmonic distortion (THDv) ≤2% linear load;
≤5% non-linear load Performance (normal mode) 88% - 90% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs Yes Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 815 x 250 x 826 Weight 164Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%

View More
In Stock: Next Day
£2570.62
£3084.74 Inc Vat.
Qty:
No Internal Batteries

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 15000 TWIN PRO2 15kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 15 kVA. The SLC 15000 TWIN PRO2 15kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=0.9
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 15000 TWIN PRO2 UPS Power (VA / W) 15000 / 13500 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110-276 V (2) Total harmonic distortion (THDi) <5% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 0.9 Total harmonic distortion (THDv) ≤2% linear load;
≤5% non-linear load Performance (normal mode) 88% - 90% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs Yes Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 815 x 250 x 826 Weight 164Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%

View More
In Stock: Next Day
£1810.30
£2172.36 Inc Vat.
Qty:
Standard Model

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 20000 TWIN PRO2 20kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 20 kVA. The SLC 20000 TWIN PRO2 20kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=0.9
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 20000 TWIN PRO2 UPS Power (VA / W) 20000 / 18000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110-276 V (2) Total harmonic distortion (THDi) <5% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 0.9 Total harmonic distortion (THDv) ≤2% linear load;
≤5% non-linear load Performance (normal mode) 88% - 90% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs Yes Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 815 x 250 x 826 Weight 166Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%

View More
In Stock: Next Day
£2775.79
£3330.95 Inc Vat.
Qty:
No Internal Batteries

Enhanced protection for mid-range systems with single-phase power supply

Salicru's SLC 20000 TWIN PRO2 20kVA UPS features on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage.

The Salicru SLC TWIN PRO2's output voltage is always single-phase, featuring a single-phase input of 20 kVA. The SLC 20000 TWIN PRO2 20kVA UPS provides a unitary output power factor, the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.

Features

On-line double conversion and DSP control technology.
Output power factor PF=0.9
Compact tower format for space saving.
Active power factor corrector for all input phases.
Multiple operating modes for better adaptability.
Equipped for parallel operation as standard, up to 3 devices.
USB and RS-232 interface for all models as standard.
Monitoring software for Windows, Linux, Unix and Mac.(downloadable)
Intelligent slot for SNMP/RS-485/optocoupler cards.
Eco-mode operation for increased efficiency.
Backup extensions available for all power ratings.
Frequency conversion function.
EPO – emergency power off.
Manual and/or automatic programmable battery test.
SLC Greenergy solution.
Operating Modes

On-line double-conversion

Double voltage conversion (AC/DC + DC/AC), providing the best degree of safety to loads Batteries

In the event of power failure, the loads continue to be powered by means of batteries Bypass

In the event of any eventuality (incident, overload, etc.), the loads continue to be powered by the input voltage. Frequency Converter

Adaptation of the output frequency to the needs of the load (50/60 Hz or 60/50 Hz). Eco-Mode

Increased efficiency up to 99%, with immediate availability of full power. Parallel Redundant

Increased safety (N+1) or capacity, with configurations of up to 3 devices. Applications

Salicru's SLC TWIN PRO2 series is the best option for providing a secure power supply to ERP systems, Business Intelligence, CRM solutions, intranets/extranets and corporate networks in the event of a wide range of possible disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.), which can cause irreparable damage or incur high costs in all of these critical systems.

Comparison Chart



Technical Specification

MODEL SLC 20000 TWIN PRO2 UPS Power (VA / W) 20000 / 18000 Technology On-line, double conversion, PFC with double DC bus Format Tower Input Rated Voltage 208 / 220 / 230 / 240 V (1) Voltage range 110-276 V (2) Total harmonic distortion (THDi) <5% Power Factor ≥0.99 Frequency 50 / 60 Hz ±10% Input protection Resettable breaker Output Rated voltage 208 / 220 / 230 / 240 V (1) Voltage accuracy (battery mode) ±1% Power factor 0.9 Total harmonic distortion (THDv) ≤2% linear load;
≤5% non-linear load Performance (normal mode) 88% - 90% Permissible overloads
(normal mode) Up to 110% for 10 min;
130% for 1 min Parallel Yes, up to 3 units (3) Synchronisation with mains ±4 Hz without mains ±0.1 Hz Programmable priority outputs Yes Crest factor 3 to 1 Manual Bypass Yes Bypass Type Hybrid Transfer time Nil Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charging Charge type I/U (constant current/constant voltage) Recharge time 9 hours to 90% Temperature voltage compensation Yes Communication Interface USB, RS-232 and relay Intelligent slot Yes, ready for SNMP / AS400 / RS485-Modbus Downloadable monitoring software For Windows, Unix, Linux and Mac Other Functions Eco-mode 4 Yes Frequency converter Yes Cold start Yes General Operating temperature 0ºC - 40ºC Relative humidity Up to 95%, non-condensing Noise level at 1 metre  Less than 60dB Dimensions (D x W x H mm) 815 x 250 x 826 Weight 166Kg Standards Safety EN 62040-1; EN 60950-1 Electromagnetic compatibility (EMC) EN 62040-2 Category C3 Operation VFI in accordance with EN 62040-3 Quality & Environmental Management ISO-9001 and ISO-14001 (1) Power reduction to 90% for 208 V input
(2) With 50% load
(3) Power reduction to 90%

View More
In Stock: Next Day
£1991.33
£2389.60 Inc Vat.
Qty:
Other Ranges Available
Salicru Online (700VA-3000VA) Tower UPS
View Range
Salicru Line Interactive (850VA-3000VA) Tower UPS
View Range
Join Our Mailing List
 
Social Links
  • Apply for Credit