Non Invasive A.C. Electrical Current Monitoring Technology
Greatly improving the drive for energy efficiency for legacy data centres.
A purpose built monitoring solution for retrofit, new build and legacy electrical installation monitoring, which enables legacy data centres to be monitored and managed, in order to regain power and cooling capacity, without scheduled power downtime associated with traditional monitoring technologies.
The CL-Amp increases visibility of power demand in a cost effective and efficient ‘non-invasive’ manner, providing clients far greater control in the ability to identify available capacity, make informed decisions, calculate ‘what-if’ scenarios, perform risk analysis and drive down costs, thereby greatly improving the drive for energy efficiency.
An open fork in the CL-Amp enables it to be placed directly over a power cable and a choice of locking ring collars to suit most international 13A, 16A and 32A cable sizes are provided. Each locking ring separates into two halves and is placed around the power cable and pushed into the CL-Amp clamping bore, retaining the cable with a neat twist and lock action. A very lightweight device, it is designed to be installed at any convenient location on the cable.
CL-Amp Features
Uses patented technology for current measurement in the data centre, computer room and PC environments.
A small compact electrical current meter capable of non-invasively measuring realtime A.C. currents on typical data centre power supply feeds rated up to 32A.
High quality robust plastic, conforming to international electrical and EMC standards.
Attachment does NOT require power down of the measured feed.
CL-Amp appears as a standard PDU input to the PowerHawk2, Hawk-i2, Hawk-i3 and Eagle-i units for remote monitoring and real time alerting.
Capable of measuring A.C. electrical currents up to 60A.
Can be used to bring monitoring functionality to non-intelligent power strips
Technical Specification
Current measuring range 1.0 Amps to 60 Amps.
Measured supply range: 90VAC ~ 250VAC.Frequency: 50Hz ~ 60Hz A.C.
Size: 134mm x 88.5mm x 41mm, Weight: 135gm
RS232/RS485 Communication link to Unite Technologies’ monitoring units: PowerHawk2, Hawk-i2, Hawk-i3 and Eagle-i. Providing SNMP data collection, monitoring, and configuration of CL-Amp.
RJ45 connector for direct connection to PowerHawk2, Hawk-i2, Hawk-i3 and Eagle-i unit.
12V DC power supply @60mA (typically supplied direct from PowerHawk2, Hawk-i2, Hawk-i3 and Eagle-i unit).
Can be calibrated to cable types to provide typically ±3% accuracy ampere current readings
Non Invasive A.C. Electrical Current Monitoring Technology
Greatly improving the drive for energy efficiency for legacy data centres.
A purpose built monitoring solution for retrofit, new build and legacy electrical installation monitoring, which enables legacy data centres to be monitored and managed, in order to regain power and cooling capacity, without scheduled power downtime associated with traditional monitoring technologies.
The CL-Amp increases visibility of power demand in a cost effective and efficient ‘non-invasive’ manner, providing clients far greater control in the ability to identify available capacity, make informed decisions, calculate ‘what-if’ scenarios, perform risk analysis and drive down costs, thereby greatly improving the drive for energy efficiency.
An open fork in the CL-Amp enables it to be placed directly over a power cable and a choice of locking ring collars to suit most international 13A, 16A and 32A cable sizes are provided. Each locking ring separates into two halves and is placed around the power cable and pushed into the CL-Amp clamping bore, retaining the cable with a neat twist and lock action. A very lightweight device, it is designed to be installed at any convenient location on the cable.
CL-Amp Features
Uses patented technology for current measurement in the data centre, computer room and PC environments.
A small compact electrical current meter capable of non-invasively measuring realtime A.C. currents on typical data centre power supply feeds rated up to 32A.
High quality robust plastic, conforming to international electrical and EMC standards.
Attachment does NOT require power down of the measured feed.
CL-Amp appears as a standard PDU input to the PowerHawk2, Hawk-i2, Hawk-i3 and Eagle-i units for remote monitoring and real time alerting.
Capable of measuring A.C. electrical currents up to 60A.
Can be used to bring monitoring functionality to non-intelligent power strips
Technical Specification
Current measuring range 1.0 Amps to 60 Amps.
Measured supply range: 90VAC ~ 250VAC.Frequency: 50Hz ~ 60Hz A.C.
Size: 134mm x 88.5mm x 41mm, Weight: 135gm
RS232/RS485 Communication link to Unite Technologies’ monitoring units: PowerHawk2, Hawk-i2, Hawk-i3 and Eagle-i. Providing SNMP data collection, monitoring, and configuration of CL-Amp.
RJ45 connector for direct connection to PowerHawk2, Hawk-i2, Hawk-i3 and Eagle-i unit.
12V DC power supply @60mA (typically supplied direct from PowerHawk2, Hawk-i2, Hawk-i3 and Eagle-i unit).
Can be calibrated to cable types to provide typically ±3% accuracy ampere current readings
Email product to a friend Print product details
View Keywording:
Customers also Purchased
X
Perfect Pairings With Your Product
Due to the size, weight and delicate nature of Data and Server Cabinets, specialist couriers are required so they arrive on site in pristine condition.
We do our utmost to bare the delivery costs meaning we can deliver your cabinet free of charge to most areas, unfortunately there are some areas of the UK we are charged a lot more to deliver to and whilst we absorb as much of this cost as we viably can in certain cases we have to pass on some of these costs. Below is a list of these areas and the additional costs of delivery per cabinet.